19
OI remote control for Pluggit Avent
Englis
h
5.1.
DECOMMISSIONING IN CAS OF DISMANTLING
Decommissioning must only be carried out by qualified per-
sonnel.
•
Disconnect the unit from power supply.
•
Disconnect all poles of the unit from the power supply
system.
5.2.
PACKAGING
The transport and protective packaging are usually manu-
factured from reusable materials.
All packaging material must be disposed of according to
local laws and regulations.
5.3.
OLD APPLIANCE
The remote control contains valuable materials and sub-
stances which should be kept separate from residual waste.
The old appliance can be delivered to the local recycling
company for recycling.
4. TECHNICAL DATA
Factory settings
Min
Max
Relative air humidity in the automatic programme
45 %
35 %
65 %
Automatic bypass
T
min
outside air temperature (T1)
15 °C
8 °C
15 °C
T
max
exhaust air temperature (T3)
24 °C
22 °C/OFF
30 °C
Preheating
T1/SET (electrical preheating)
-2 °C
-2 °C/OFF
-10 °C
T1/SET (geothermal preheating)
0 °C
Ventilator settings
Fan OFFSET (Gears between levels 1 - 2- 3)
25 gears
10 gears
30 gears
Maximum speed of the ventilator (level 4)
100 %
like level 3
100 %
Filter timer
Filter change intervals
360 days
90 days
360 days
5. DECOMMISSIONING/DISPOSAL