Adam | 21
EN
Adam is connect to a heat pump (Elga)
Adam cannot detect Elga automatically.
Support for the Elga can be activated on
the Adam to make the system work. Please
send an email to support@plugwise.com,
so we can activate this feature. Once
support is turned on, the Elga specific
setting become visible in the web interface
of Adam.
Also check the detected boiler protocol at
Adam, see page 20. This should be
OpenTherm.
In addition it is important that Elga uses
her weather dependent regulation. Elga
must then be connected as described in
scheme K5 or K6 in the Elga installer
manual.
Dip switches on Elga:
» Turn the dip switches B1 & B2 on
» Turn the dip switch A6 on.
» Set the dip switches A1 & A3 to the
house
» Set the dip switch A8 depending on
the communication with the boiler.
Adam is connected to an on/off boiler
• Fill in the maximum boiler
temperature that is set on your boiler
at
Settings > Heating system > Heating
.
Does your boiler use a weather-
dependent regulation? Activate this in
the web interface of Adam and fill in
the maximum boiler temperature as is
set on your boiler for both low and
high outside temperature.
2. Connect to the boiler