33
34
40.00MΩ
10kΩ
+2.0% of rdg + 3 dgts
Capacitance
Range
Resolution
Accuracy
4.000nF
1pF
+5.0% of rdg+50 dgts
40.00nF
10pF
+5.0% of rdg + 7 dgts
400.0nF
0.1nF
+3.0% of rdg + 5 dgts
4.000uF
1nF
40.00uF
10nF
400.0uF
0.1uF
4.000mF
0.001mF
+10% of rdg + 10 dgts
40.00mF
10.00mF
Frequency
Range
Resolution
Sensitivity
Accuracy
4.000kHz
1Hz
>5V RMS
+1.5% of rdg + 3 dgts
40.00kHz
10Hz
400.0kHz
100Hz
4.000MHz
1000Hz
40.00MHz
1kHz
>15V RMS
+2.0% of rdg + 4 dgts
Duty Cycle
Range
Resolution
Accuracy
0.5%~99.0 %
0.1%
+2% of rdg + 5 dgts
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 100kHz
Sensitivity: >5V RMS
Pulse Width
Range
Resolution
Accuracy
1.0~ 20.0ms
0.1ms
+2% of rdg +20 dgts
Type-K Temperature
Range
Resolution
Accuracy
-30oC~ 1000oC
1 oC
+3% of rdg +5 oC/8 oF
(Meter only, probe accuracy
not included)
-22 oF~1832 oF
1oF
Sensor: Type K Thermocouple
Diode Test
Test current
Resolution
Accuracy
1.0mA typical
1 mV
+5% of rdg +15 dgts
Open circuit voltage: 3.0V dc typical
Audible continuity
Audible threshold: Less than35Ω Test current: <1mA dc typical
Maintenance
REPLACING THE BATTERY
WARNING
: To avoid electric shock, disconnect the test leads
from any source of voltage before removing the battery door.
1. When the batteries become exhausted or drop below the
operating voltage, “BAT” will appear in the right-hand side of the
LCD display. The battery should be replaced.
2. Follow instructions for installing battery. See the Battery
Installation section of this manual.
3. Dispose of the old battery properly.
WARNING:
To avoid electric shock, do not operate your meter
until the battery door is in place and fastened securely.