0507280010/010312/E MNF
EN - 3
ENGLISH
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
These data can be found on the identification plate.
1.1
Identification of the product
The identification plate contains, among other things, the
following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2
General description
The MNF is a portable fan that provides extraction in confined
spaces and other hard to reach areas. For this purpose an
extraction hose with nozzle and magnetic foot needs to be
connected. Exhaust and/or extension hose is optional.
The MNF is mounted on a frame for easy removal.
A motor protection switch prevents overheating of the motor.
The MNF does not provide filtration.
1.3
Product combinations
In order to operate the portable fan, the use of the following
product is required:
- SUS-5/160 (5 m extraction hose with magnetic foot)
1.4
Options and accessories
The following products can be obtained as an option and/or
accessory:
- EXS-5/160 (5 m exhaust/extension hose)
1.5
Technical specifications
1.6
Pressure drop
Refer to Fig. I on page 33 (MNF without hoses).
A = Static pressure (Pa)
B = Airflow (m
3
/h)
Pressure drop per 5 m hose: 90 Pa.
1.7
Ambient conditions
2.1
Components
The product consists of the following main components and
elements:
Fig. 2.1
A inlet opening with protective grid
B fan housing
C fan wheel
D motor protection switch
E carrying frame
F motor
G outlet opening with protective grid
PREFACE
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the necessary
caution, may damage the product or cause serious
personal injury.
WARNING!
Denotes risk of electric shock.
WARNING!
Fire hazard! Important warning to prevent fire.
1
INTRODUCTION
MNF
Inlet diameter
Ø 160 mm (Ø 6.30 in.)
Outlet diameter
Ø 160 mm (Ø 6.30 in.)
Weight (net)
17 kg (37.5 lbs)
Supply cable
6 m (19.7 ft); without
plug
Fan type
radial
Unrestricted airflow
2400 m
3
/h (1413 CFM)
Net extraction capacity:
- MNF + SUS-5/160
- MNF + SUS-5/160 + EXS-5/160
- 1300 m
3
/h (765 CFM)
- 1150 m
3
/h (677 CFM)
Noise level (incl. SUS-5/160)
69 dB(A) according to
ISO 3746
Insulation class
F
Protection class
IP 55
SUS-5/160
Length
5 m (16.5 ft)
Hose diameter
Ø 160 mm (6 ft)
EXS-5/160 (option)
Length
5 m (16.5 ft)
Hose diameter
Ø 160 mm (6 ft)
Refer to the available product data sheet for detailed
product specifications.
Min. operating temperature
5°C (41°F)
Nom. operating temperature
20°C (68°F)
Max. operating temperature
45°C (113°F)
Max. relative humidity
80%