Code
Warning
Action
Reset
A
uto / Manual
Warning LED
Buzzer
W109
Slave board(s)
The system cannot detect the
amount of set filter cartridges.
Check cable connections and dip
switch positions on each slave
board.
A
√
√
W110
External warning
signal
Check external device.
A
√
W111
PID setpoint
warning
The frequency inverter is unable to
reach the PID setpoint. Lower the
PID setpoint or replace the filter
cartridges.
A
√
√
W112
Communication
ControlPro/HMI
A
√
√
W113
Frequency inverter
parameters
changed
Critical parameters for
communication with the frequency
inverter are set incorrectly. Select
the button to recover the
communication parameters.
M
√
W114
External Sensor
- Fan Pressure
Sensor connection fault. Examine
the cable and connections and
repair/replace if necessary.
A
√
W115
External Sensor
- Filter pressure
Sensor connection fault. Examine
the cable and connections and
repair/replace if necessary.
A
√
W116
External Sensor
- Dustbin Level
Sensor connection fault. Examine
the cable and connections and
repair/replace if necessary.
A
√
W117
Service Mode
The ControlPro/HMI is locked and
the system is in service mode.
Limited functionality, control only
by separate ControlPro/Panel.
A
√
A
B
C
D
E
F
Code
Warning
Action
Reset
A
uto / Manual
Warning LED
Buzzer
W118
OilShield
The OilShield (limestone feeder) is
not functioning properly. Check the
cable and connections and repair/
replace if necessary. Consult the
OilShield manual for more detailed
information on the specific warning
code.
A
√
7.2 Alarms
All ALARM alerts result in a full screen pop-up alert and are accompanied by an acoustic
signal (buzzer).
Fig. 7.1 Example of an ALARM screen
Alarms will cause the HMI to automatically switch to Manual Mode! When the problem,
which causes the alarm has been solved, you can return to Automatic Mode.