0507345000/PHV/011213/G
EN - 12
7.2.2 Replacement of the HEPA filter
Use the plastic bag that contains the new HEPA filter
to exchange the filter for a new one. Put the used
HEPA filter carefully in the plastic bag and close it with
a tie wrap or similar.
• Remove the outlet cover by loosening the two
screws (D)
• Remove the HEPA filter (E).
• Place a new HEPA filter in the correct position
(open side at the top); to facilitate this, apply some
suds to the seals.
• Remount the outlet cover by fastening the two
screws. Make sure that the outlet cover is in the
right position; the open side of the HEPA filter
should correspond with the smallest opening of the
outlet cover.
ATTENTION: By taking out the HEPA filter, its seals
will deform. For this reason, never replace a used HEPA
filter, but always place a new one.
8
TROUBLESHOOTING
If the machine does not function (correctly), please
consult the checklist below to see if you may remedy
the error yourself. If not, please contact your supplier.
.
WARNING!
Always switch OFF the machine and remove
the mains plug from the wall socket before
carrying out any repairs.
The repair activities in the table below indicated by
[1]
can be carried out by the user; other activities shall
only be carried out by qualified personnel.
.
Always replace all motor seals when replacing
or carrying out maintenance on the motors.
If the supply cord is damaged, it must be replaced by
the manufacturer or its service agents or a similary
qualified person in order to avoid hazard.
9
SPARE PARTS
For spare filters and parts available for the machine
consult the exploded view (see fig. 5 on page 45). The
machine is standard supplied with two sets of spare
carbon brushes including seals.
• 0000102275
Pre filter
• 0000102284
Tumbler switch 0-I (USA/Canada)
• 0328250010
Pressure switch (IFA)
• 0806010120
Handle black
• 9820034120
Carbon brushes (2 sets); 230V
• 9820034130
Carbon brushes (2 sets); 120V
• 9840251030
Motor 120V/60Hz, incl. seals
• 9840251040
Motor 230V/50-60Hz; incl. seals
• 9850040030
Wheel set (2 pieces, excl. wheel
covers)
• 9850040040:
Wheel covers yellow (2 pieces)
• 9850060140
HEPA filter H12
• 9850060230:
Dura-H filter with integrated
prefilter
• 9850070090
Activated carbon filter FAC-HV
• 9850070100
Top cover PHV; 230V/1ph/50Hz
• 9850070130
Draw latch (set of 2; to be ordered
per 10 sets/2)
• 9850070150
Outlet cover
• 9850070200
Top cover PHV-I; 230V/1ph/50Hz
• 9850070700
Top cover PHV; 120V/1ph/60Hz
• 9850080140
Seals main filter (set)
• 9880030030
Control panel + PC board PHV;
120-230V/1ph/50Hz
• 9880030040
Control panel + PC board PHV;
120-230V/1ph/50Hz (IFA)
• 9880030050
Control panel + PC board PHV;
120V/1ph/60Hz (USA/Canada)
Problem
Possible cause
Solution
Motor does
not start.
No mains voltage. Check the mains
voltage.
Supply cord
defective.
Repair or replace
the supply cord.
Carbon brushes
worn.
Replace the carbon
brushes.
Motor defective.
Replace both
motors.
Extraction
capacity
insufficient.
Main filter
polluted.
Replace both main
filter and HEPA
filter
[1]
.
Extraction hose
damaged or leak.
Replace the
extraction hose
[1]
.
Seals damaged or
leaking.
Replace the seals.
Motor stops
auto-
matically.
Thermal protection
is activated.
Check that the
cooling slits
underneath the top
cover and/or the
outlet are not
obstructed.
Dust or
smoke
coming out
of the outlet
grid.
Filter torn or
placed incorrectly.
Replace the filter
or position it
correctly
[1]
.
Problem
Possible cause
Solution