MOUNTING INSTRUCTION
MEASUREMENT PROCEDURES
1. Exhaust pipe
2. Stack adapter
3. Exhaust pipe height
4. Distance between gate and exhaust pipe
5. Distance C/C exhaust pipe and vehicle body.
Back-In
Measure the distance between the gate and the exhaust pipe.
This distance (4) plus 1 m (minimum) is the required length of the rail.
Note! The vehicle must be as far away from the gate as possible in back-in position.
Drive-Through
Measure the distance between the exit and entrance gate. This distance minus 0.5-1.0 m/1,6-3,3´
(depending on free space from gate) is the required length of the rail.
The VSR is normally positioned immediately after the gate at a distance of approx. 50-100 mm/2-4”.
Check the height of the exhaust pipe, see further under measurement procedures, see next page for required
space for exhaust pipe.
The distance C/C exhaust pipe and truck body (5) is the required rail position from the truck body.
Gate
2
1
3
4
5