Activating
Proper activation of a Cardox Tube should be done with an activating machine. Dis-
connect the short-circuit and insert and tighten the leads into the screw-down connec-
tors on the activating machine.
READ the instructions on the activating machine to become familiar with its operat-
ing procedures. Verify by sight and sound that everyone is clear. Then, hold down
the charging button until the red indicator light comes on to signal that the activating
machine is now charged and ready. Depress the firing button and the Cardox Tube
will be initiated.
Misfires
CAUTION
– Misfired tubes can be partially energized and may be very hot to the
touch. Consider every misfire to be HOT until verification that it is not.
If a Cardox Tube does not fire when activated, first check for connection problems
such as loose wires and check the continuity (1-3 ohms). If a connection has been
found as the source of the misfire, clear the area again and try to reactivate.
If no connection problem exists, the very FIRST thing to be done is to release the
pressure inside the Cardox Tube. Locate the release valve on the activating head
and open it with a 1/4” Hex Wrench which will let the pressurized CO
2
exit the tube
to atmosphere. This must be done before anything else, since once the pressure is
relieved from inside the tube, that tube can no longer discharge unexpectedly. If the
continuity is out of range the heater will need to be replaced (see page 6).
Removal
Disconnect wires from the activating machine and short-circuit them, remove wires
and tape from the activating head connections, whether a tube is charged or dis-
charged, before removal from the material. The tube can now be safely removed and
rebuilt if neccesary.
6. STANDARD OPERATING PROCEDURES -SPECIFIC AREAS
Purpose and Scope
To provide the user with the proper and most current operating procedures for safe
Cardox tube preparation, tube filling, and tube activation. Also to highlight issues of
safe operation of the Cardox system. and to provide an understanding of the Cardox
system and its usefulness as an in operation tool for reducing process blockage.
Responsible Roles
2.00 Pneumat Systems, Inc. endeavors to provide the users of the Cardox system the
proper and safe operating procedures
2.01 The user of the Cardox system is to be aware of the safe procedures and follow
them.
2.02 The user of the Cardox system is encouraged to respect the proper handling
procedures and to not take short cuts in the use of the Cardox system.
2.03 The user is encouraged to follow all the proper steps in preparation, filling and
activating the Cardox tube.
Summary of Contents for Cardox CO2
Page 1: ...A B C D 8 7 6 TECHNICAL MANUAL 110 Mohr Drive Mankato MN 56001 1 800 458 9446 www pneumat com ...
Page 22: ...Cardox Techical Manual Page 22 5780 0005 Cardox Fill Stand Assembly Parts List ...
Page 25: ...Cardox Techical Manual Page 25 5730 0003 Auto Fill Activating Head w Eyebolt Parts List ...
Page 27: ...Cardox Techical Manual Page 27 Series 3700 Firing Head Tube Body Discharge Head Parts List ...
Page 28: ...Cardox Techical Manual Page 28 Series 5700 Firing Head Tube Body Discharge Head Parts List ...