24
Pub. No. OM-A-10E — April 2004
D. Excessive flow through mufflers.
1. Check valves leaking.
NOTE:
To test for leaking, check valves
during regeneration cycle, shut the
purge adjusting valve. If gas is still
passing through, it is an indication of
leaking check valves.
2. Inlet valves did not switch.
3. Purge valve stays open.
4. Repressurizing valve does not
close.
5. Diaphragms ruptured in valves
(EE models).
1. Repair or replace faulty check
valves.
2. See F1 to F4.
3. Check purge solenoid and valve.
Repair or replace faulty purge
valve or solenoid.
4. Check repressurizing solenoid
and valve. Repair or replace faulty
repressurizing valve or solenoid.
5. Replace diaphragms.
E. No gas flow through the dryer.
1. Both inlet valves closed due to low
inlet pressure.
1. Manually open the inlet valve by
turning the shaft or the ON
actuator.
F. Failure to switch alarm light.
1. Inlet valves did not switch.
2. Faulty timer.
3. Insufficient pilot air pressure.
4. Cylinder leaking or seized up.
1. Check pilot air solenoid valve.
Repair if necessary.
2. Replace timer.
3. Clean or replace pilot filter
element.
4. Repair or replace pilot air
cylinder.
G. High pressure drop in dryer.
1. Desiccant retainer screens
plugged.
2. Excess flow.
3. High purge flow.
4. Purge valve stays open.
5. Repressurizing valve stays open.
1. Replace desiccant retainer
screens.
2. Check inlet flow conditions.
3. Check and reset purge pressure.
4. Check repressurizing solenoid
valve, repair or replace if
necessary. Check timer.
5. See D4.
H. Dryer fails to purge.
1. Orifice plate plugged.
2. Purge valve fails to open.
3. Purge valve closed.
4. Purge check valve blocked.
1. Clean the orifice plate.
2. See G3.
3. Reset proper purge pressure.
4. Inspect purge check valve.
Replace if necessary.
I. High dewpoint alarm light.
See chart on alarm conditions.
J. Moisture indicator color turned pink
(wet conditions).
1. Bleed valve closed.
2. See probable cause on #1.
1. Open the bleed valve to allow
small amount of air to constantly
flow through the gel.
K. Tower fails to pressurize.
1. Purge valve stays open.
2. Repressurizing valve faulty.
3. Diaphragms ruptured in valves
(EE models).
1. See G3.
2. See D4.
3. Replace diaphragms.
Table 1 — Troubleshooting Guide for Regenerative Dryers, continued
Symptoms
Cause
Remedy