Introduction

The  F75  air  filters  remove  impurities  from  the  air  stream  two 
ways — dynamically by centrifugal force, by which the deflector 
throws out heavier particles and entrained water, and statically 
through  the  filter  element  itself,  which  filters  out  the  smaller 
particles.    The  F75  filter  provides  enough  filtration  for  most 
pneumatic  applications.    However,  in  situations  where  water 
and/or oil aerosols must also be filtered out, an F71 coalescing 
filter  should  be  installed  also.    Follow  these  instructions  when 
installing, operating, or servicing the product.

Application Limits

These  products  are  intended  for  use  with  compressed  air  in 
industrial  applications.    For  other  applications,  consult  factory 
before use.

Maximum Recommended Pressure Drop:

   

kPa  PSIG 

bar

  Particulate Filter 

70 

10 

  0.7

With Polyurethane Bowl with Polyethylene  
Bowl Guard

   

kPa  PSIG 

bar

  Operating Pressure Maximum 

1034 

150 

10.2

  Operating Temperature Range

  

4°C to 49°C  

  (40°F to 120°F)

With Metal Bowl

   

kPa  PSIG 

bar

  Operating Pressure Maximum 

2068 

300 

21.0

  Operating Temperature Range

  

4°C to 82°C  

  (40°F to 180°F)

With Metal Bowl with Wrap Around Sight Gauge

   

kPa  PSIG 

bar

  Operating Pressure Maximum 

1723 

250 

17.0

  Operating Temperature Range

  

4°C to 66°C  

  (40°F to 150°F)

ANSI Symbols

Installation

All FRL components are individually tapped (NPT or BSPP) to 
allow direct mounting to piping.  Also, each component comes 
equipped  with  the  necessary  screws  and  O-rings  to  enable 
connection  to  other  components  of  the  same  series  without 
the need for pipe nipples or special adaptors.  Before installing, 

CAUTION

Polyurethane  bowls,  sight  glass  and  sight  domes  on  these  units  may  be 
attacked by certain chemicals. Never use solvents like carbon tetrachloride, 
trichlorethylene, acetone, or paint thinner to clean any parts. These elements 
can cause crazing or failure of the plastic parts. The polyurethane resin parts 
are compatible with most hydrocarbon based synthetic lubricants but, before 
using, check with the manufacturer of the lubricant or oil for compatibility 
with polyurethane resin.

TO  CLEAN  POLYURETHANE  BOWLS  USE  MILD  SOAP  AND WATER 
ONLY!

!

  

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

   WARNING

To avoid unpredictable system behavior that can cause personal injury 

and property damage:

•  Disconnect  electrical  supply  (when  necessary)  before  installation, 

servicing, or conversion.

•  Disconnect air supply and depressurize all air lines connected to this 

product before installation, servicing, or conversion.

•  Operate within the manufacturer’s specified pressure, temperature, 

and other conditions listed in these instructions.

•  Medium  must  be  moisture-free  if  ambient  temperature  is  below 

freezing.

•  Service according to procedures listed in these instructions.
•  Installation,  service,  and  conversion  of  these  products  must  be 

performed  by  knowledgeable  personnel  who  understand  how   

pneumatic products are to be applied.

•  After installation, servicing, or conversion, air and electrical supplies 

(when necessary) should be connected and the product tested for 

proper  function  and  leakage.  If  audible  leakage  is  present,  or  the 

product does not operate properly, do not put into use.

•  Warnings and specifications on the product should not be covered by 

paint, etc. If masking is not possible, contact your local representative 

for replacement labels.

!

Safety Guide

 

For more complete information on recommended application guidelines, see 
the Safety Guide section of Pneumatic Division catalogs or you can download 
the 

Pneumatic Division Safety Guide

 at: www.parker.com/pneumatics

          WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE 
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED 
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY 
DAMAGE.

This  document  and  other  information  from  The  Company,  its  subsidiaries 
and authorized distributors provide product and/or system options for further 
investigation  by  users  having  technical  expertise.  It  is  important  that  you 
analyze all aspects of your application, including consequences of any failure 
and review the information concerning the product or systems in the current 
product catalog. Due to the variety of operating conditions and applications for 
these products or systems, the user, through its own analysis and testing, is 
solely responsible for making the final selection of the products and systems 
and assuring that all performance, safety and warning requirements of the 
application are met.
The products described herein, including without limitation, product features, 
specifications, designs, availability and pricing, are subject to change by The 
Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION 
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. 
CONTACT YOUR LOCAL REPRESENTATIVE

.

!

!

A

Filter

w/Manual Drain

Adsorber

w/Manual Drain

Reviews: