background image

Pb

LEAD FREE

in compliance with RoHS

ELEKTROBOCK CZ s.r.o.

Blanenská 1763
Kuřim 664 34
Tel.: +420 541 230 216

The guarantee period is 2 years. In the case of gua-
rantee or post-guarantee service, send the product 
to the manufacturer’s address.

MADE IN CZECH REPUBLIC

DECLARATION OF CONFORMITY

We, ELEKTROBOCK CZ s.r.o., herewith declare that the pro-
duct PH-BP1-V is in conformity with basic requirements and 
other corresponding provisions of the directive 1999/5/EC.
Kurim 1.8.2009                                         on www.elbock.cz

In the PocketHome

®

 system, the transmitter detects current room temperature, receives information on 

the required temperature from the central unit, and sends requirements to the receiver according to the 
temperature difference. In connection with up to 9 PH-BP1-V transmitters, PH-BP1-P9 means a system 
for complete control of fl oor heating.

Technical parameters

Power supply

2 x 1.5 V alkl. baterie type AA 

Communication type

two-way

Frequency

433.92 MHz

HF output

< 10 mW

Number of temp.changes 6 na každý den 
Hysteresis

0.1°C to 5°C by steps of 0.1°C

Min. program. time

10 minutes

Preset temperature range 3°C to +40°C
Temperature setting

by 0.5°C

Min. indication step

0.1°C

Measurement accuracy

± 0.5°C 

Protection class

IP20

Working temperature

0°C to +40°C

CERTIFICATE OF GUARANTEE

(guarantee period for the product amounts to 2 years)

product No.:

date of sale:

stamp of shop:

examined by:

Advantages:

- In the PocketHome

®

 system, central control 

  from one point, quick overview of temperature 
  in every room.
- Temperature control in every room.
- By request, the receiver controls the distributor 
  thermo-valves and pump.
- The system is also able to work in autonomous 
  mode without the central unit.
- The E-EPROM memory keeps the codes even 
  in the case of power failure.
- Up to 30% energy saving.

up to
9 thermostats

www.elbock.cz

Summary of Contents for PH-BP1-V

Page 1: ...peratures information button when pushed in the AUTO mode it gradually shows information on the required temperature PO t current hour temperature CL O tE P operating hours SU MA and day dE n confirmation button ENTER for selection of functions and temperature setting 1 indication of the preset time and temperature program 2 indication of the selected function AUTO MANU PROG etc 3 indication of ant...

Page 2: ...on an external wall 2 Install the transmitter indoors as far as possible at least 0 5 m from big metal objects and from power lines to avoid interference of signal reception 3 We recommend that the installation be done by a person adequately qualified in electrical engineering 4 To prevent interference and affection of systems every system is protected by its unique factory saved code 5 For correct...

Page 3: ...button chose the PA r parameters function with the confirm with i PA r1 appears on the display Confirm with the i and with the choose the option for displayed data in the basic mode t current temperature display C current time display Confirm your choice by pushing the i button again PA r2 economical temperature 17 C by default PA r2 appears on the display Confirm with the i button and set the economi...

Page 4: ...to the heating system used with the see the table confirm by i button PA r7 Summer mode PA r7 appears on the display push the i button Choose in the summer time without heating Choose the mode with the button then push the i button The LE tr symbol and temperature time value alternate on the display PI r1 Time period of PI control If you choose PI control in PA r5 you must set its parameters Choose...

Page 5: ...ostat is activated in the PocketHome system see page 7 Push the i button or Fce button to return to function selection PA r9 firmware version number factory setting restoration PA r9 appears on the display This parameter is only informative and shows the firmware version number Push the i button or Fce button to return to function selection To restore factory settings push the P and button all chang...

Page 6: ...indication AUTO or MANU message on the display is LIT connected device switched ON AUTO or MANU message on the display is FLASHING connected device switched OFF OTHER FUNCTIONS Short term temperature change in the AUTO mode Push the button in the AUTO mode thus you can change the required temperature for a short time the thermostat maintains this temperature until the next temperature change given...

Page 7: ...pears on the display Push the Test button on the central unit in the ACTIV mode for the given BP1 thermostat see the PH CJ37 manual The Pa rA address will be assigned automatically Push the Test button again and the thermostat is activated in the PockerHome system and primarily controlled from the PH CJ37 Plus central unit the AUTO MANU message and current time temperature appear simultaneously on...

Page 8: ...r complete control of floor heating Technical parameters Power supply 2 x 1 5 V alkl baterie type AA Communication type two way Frequency 433 92 MHz HF output 10 mW Number of temp changes 6 na každý den Hysteresis 0 1 C to 5 C by steps of 0 1 C Min program time 10 minutes Preset temperature range 3 C to 40 C Temperature setting by 0 5 C Min indication step 0 1 C Measurement accuracy 0 5 C Protectio...