background image

1. Switch off the main circuit breaker.
2. Connect the receiver acc. to the diagram.
3. Switch on the main circuit breaker; 

the green diode 

flashes

on the receiver; thus the receiver is ready for 

further setting.

4. Shortly press the 

FUNCTION BUTTON

for about 

1.5 s 

(the green and red diode are flashing alternately).

5. On the PH-BSP control unit, press the “

Test”

button in 

the 

ACTIV

mode to activate the SP 

switching components (see page 10 
of the PH-BSP instructions).

6. If the code has been learned correctly,

the green and red diodes flash 
simultaneously.

LED 2

LED 1

empty memory, code not learned

code learned

FLASHING ALTERNATELY

= code learning mode

FLASHING SIMULTANEOUSLY

= code has been learned

SIMULTANEOUS LONG FLASH

= code was ERASED

relay switched

ERROR

(if no signal is received from the transmitter 

within approx. 6 hours, it switches to the 2-min-ON /
8-min-OFF mode). LED flashes only if the relay is on, 
i.e. for 2 minutes.

EXPLANATION:

LIT

UNLIT

FLASHING

FUNCTION

ACTIVATION PROCEDURE

INDICATION DIODES

ph_sp1_en:Layout 1  18.3.2011  13:19  Page 3

Summary of Contents for PH-SP1

Page 1: ...ting instructions Control of electric heating systems Component of the PocketHome system Two way radio communication at 433 92 MHz The connected electric appliance is switched according to the required temperature The control unit PH BSP is the pilot component ph_sp1_en Layout 1 18 3 2011 13 18 Page 1 ...

Page 2: ... max 16 A L N FUNCTION BUTTON R SHORT PRESSING for about1 5s coding LONG PRESSING for about 5s RESET deleting the code from the memory the green and red LEDs flash simultaneously PH SP1 is used for switching the heating device in connection with the PH BSP control unit The big advantage is mounted directly into the installation box ph_sp1_en Layout 1 18 3 2011 13 18 Page 2 ...

Page 3: ... see page 10 of the PH BSP instructions 6 If the code has been learned correctly the green and red diodes flash simultaneously LED 2 LED 1 empty memory code not learned code learned FLASHING ALTERNATELY code learning mode FLASHING SIMULTANEOUSLY code has been learned SIMULTANEOUS LONG FLASH code was ERASED relay switched ERROR if no signal is received from the transmitter within approx 6 hours it ...

Page 4: ...ation type two way Frequency 433 92 MHz Sensitivity 92 dBm Range 150 m in free area 20 m in built up area Output relay max 16A 250 VAC Protection IP20 and higher acc to the installation Working temperature 0 to 40 C Dimensions LxWxD 49 5 mm x 45 5 mm x 26 mm in compliance with RoHS Pb LEAD FREE MADE IN CZECH REPUBLIC ELEKTROBOCK CZ s r o Blanenská 1763 Kuřim 664 34 Tel fax 420 541 230 216 http www...