1. Switch off the main circuit breaker.
2. Connect the receiver acc. to the diagram.
3. Switch on the main circuit breaker;
the green diode
flashes
on the receiver; thus the receiver is ready for
further setting.
4. Shortly press the
FUNCTION BUTTON
for about
1.5 s
(the green and red diode are flashing alternately).
5. On the PH-BSP control unit, press the “
Test”
button in
the
ACTIV
mode to activate the SP
switching components (see page 10
of the PH-BSP instructions).
6. If the code has been learned correctly,
the green and red diodes flash
simultaneously.
LED 2
LED 1
empty memory, code not learned
code learned
FLASHING ALTERNATELY
= code learning mode
FLASHING SIMULTANEOUSLY
= code has been learned
SIMULTANEOUS LONG FLASH
= code was ERASED
relay switched
ERROR
(if no signal is received from the transmitter
within approx. 6 hours, it switches to the 2-min-ON /
8-min-OFF mode). LED flashes only if the relay is on,
i.e. for 2 minutes.
EXPLANATION:
LIT
UNLIT
FLASHING
FUNCTION
ACTIVATION PROCEDURE
INDICATION DIODES