background image

8 594012 22186 4

CERTIFICATE OF GUARANTEE

(guarantee period for the product amounts to 2 years)

product No.:

date of sale:

stamp of shop:

examined by:

In case of guarantee or 

post-guarantee service,
send the receiver to the

manufacturer’s address.

DECLARATION OF CONFORMITY 

We, ELEKTROBOCK CZ s.r.o., herewith declare that our product PH-SP1 is in 
conformity with the basic requirements and other respective provisions of the 
directive 1999/5/ES. 

Issued: 1.09.2008

TECHNICAL PARAMETERS

Power supply

230 V/ 50 Hz

Communication type two-way  
Frequency

433,92 MHz

Sensitivity

< -92 dBm 

Range

150 m 

(in free area), 

20 m 

(in built-up area)

Output

relay, max.16A/ 250 VAC

Protection

IP20 

and higher acc. to the installation

Working temperature 0 to 40°C
Dimensions 

(LxWxD)

49,5 mm x 45,5 mm x 26 mm

in compliance with RoHS

Pb

LEAD FREE

MADE IN CZECH REPUBLIC

ELEKTROBOCK CZ s.r.o.

Blanenská 1763
Kuřim 664 34 
Tel./fax: +420 541 230 216

http:// www.elbock.cz

PH-SP1 is suitable for switching heating panels, direct heaters,
radiant panels, heating mats, etc. 

It switches the connected 

device according to the information received from the control unit.
To be installed in internal rooms. Do not locate near power lines!

ph_sp1_en:Layout 1  18.3.2011  13:19  Page 4

Summary of Contents for PH-SP1

Page 1: ...ting instructions Control of electric heating systems Component of the PocketHome system Two way radio communication at 433 92 MHz The connected electric appliance is switched according to the required temperature The control unit PH BSP is the pilot component ph_sp1_en Layout 1 18 3 2011 13 18 Page 1 ...

Page 2: ... max 16 A L N FUNCTION BUTTON R SHORT PRESSING for about1 5s coding LONG PRESSING for about 5s RESET deleting the code from the memory the green and red LEDs flash simultaneously PH SP1 is used for switching the heating device in connection with the PH BSP control unit The big advantage is mounted directly into the installation box ph_sp1_en Layout 1 18 3 2011 13 18 Page 2 ...

Page 3: ... see page 10 of the PH BSP instructions 6 If the code has been learned correctly the green and red diodes flash simultaneously LED 2 LED 1 empty memory code not learned code learned FLASHING ALTERNATELY code learning mode FLASHING SIMULTANEOUSLY code has been learned SIMULTANEOUS LONG FLASH code was ERASED relay switched ERROR if no signal is received from the transmitter within approx 6 hours it ...

Page 4: ...ation type two way Frequency 433 92 MHz Sensitivity 92 dBm Range 150 m in free area 20 m in built up area Output relay max 16A 250 VAC Protection IP20 and higher acc to the installation Working temperature 0 to 40 C Dimensions LxWxD 49 5 mm x 45 5 mm x 26 mm in compliance with RoHS Pb LEAD FREE MADE IN CZECH REPUBLIC ELEKTROBOCK CZ s r o Blanenská 1763 Kuřim 664 34 Tel fax 420 541 230 216 http www...

Reviews: