Maintenance

• Checkings and maintenance procedure

Before and after each use, check that:

 

1) No visible damage is found and no part is missing

 

2) The inlet coupling swivels freely

 

3) The shutoff operates normally

 

4) The selective flow ring functions normally

 

5) The selective flow pattern ring functions normally.

• The inlet coupling leaks or does not swivel freely

 

- Remove the screw mark 45

 

- Remove all ball bearings mark 42 while turning the coupling mark 43

 

- Remove the inlet coupling mark 43 and 46.

 

- Replace inlet gasket mark 41

 

- Clean and apply grease (Loctite 8106) to the ball bearing seat mark 1 and 43

 

- Apply grease on gasket mark 41 (Loctite 8106)

 

- Install inlet coupling mark 43 on the body mark 1

 

- Insert all balls mark 42

 

- Glue (Loctite 243) and screw mark 42

 

- Ensure that the inlet coupling turns freely

• The shutoff leaks or does not swivel freely

Ensure that no foreign body prevents the shutoff from turning. If there is not any, dismantle the shutoff 

device as follows: 

 

- Remove the inlet coupling mark 43 and 46 as detailed above

 

- Remove the screws mark 5

 

- Remove the ball mark 2 

 

- Remove ball axis mark 3 by pulling inward

 

- Remove ball gasket mark 18 and gasket mark 19

 

- Clean and replace if necessary gaskets mark 19 and ball gasket mark 18

 

- Grease and reassemble gasket mark 19 and ball gasket mark 18

 

- Replace gaskets mark 4

 

- Install the handle (pay attention to the mark "OPEN" and "CLOSE")

 

- Grease and reassemble axis mark 3 and gasket mark 4. The slot guidance for the handle should  

 

be horizontal and the handle in "OPEN" position 

 

- Reassemble the ball mark 2 

 

- Replace gasket mark 6

 

- Grease and reassemble gasket mark 6 (pay attention to not grease the screw mark 5)

 

- Glue (Locite 243) and screw mark 5

 

- Reassemble the inlet coupling mark 43 and 46 as detailed above

• The flow pattern ring doesn’t turn

 

- Remove the index knob mark 31 (pay attention to the spring mark 32 and the ball mark 33)

 

- Remove the stream index mark 39

 

- Remove head ring mark 34

 

- Replace gaskets mark 23

 

- Clean and grease (Locite 8106) grooves and contact aeras of parts mark 22 and 34

 

- Reassemble head ring mark 34

 

- Glue (Locite 243) and screw stream index mark 39 until a slight contact with bore cover mark 22  

 

and untight on a 1/4 revolution.

Summary of Contents for Turbokador 500

Page 1: ...10400 Nogent sur Seine FRANCE Tel 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email france pok fr Web www pok fr FIREFIGHTING EQUIPMENT TURBOKADOR 500 Selectable gallonage 500 l min MOP_LAM_01289_EN Rev...

Page 2: ...OK SAS Illustrations are only informative 2 Identification FIELD VALUE Type of product Fire nozzle Product Turbokador 500 Selectable gallonage fire nozzle 500 l min Product referenced Ref 27691 25217...

Page 3: ...Characteristics 7 Mechanical Characteristics 7 COMPLIANCE WITH STANDARD EN 15182 2 8 1 General data 8 2 Flow chart 8 3 Mechanical System 8 4 Prescriptions 9 OVERALL DIMENSIONS 10 USE 11 Before placin...

Page 4: ...allowed only in compliance with procedures described in this manual and therefore does not affect the warranty If the equipment is repaired the spare parts must be supplied by POK SAS If not technical...

Page 5: ...ons it is imperative to 1 Cut of power supply as soon as possible 2 Maintain a safety distance as far as possible 3 To use a spray with a minimum 30 angle Before placing the nozzle in service check 1...

Page 6: ...g 3 Tactile indicator for flow rate setting 4 Stream pattern selection ring 5 Polyurethane bumper guard 6 Tactile indicators for stream pattern 7 Stem 8 Spinning teeth 9 Shutoff handle 10 Pistol grip...

Page 7: ...acteristics DESIGNATION VALUE Flow rate 150 l min 6 bar 40 GPM 87 PSI position 1 250 l min 6 bar 66 GPM 87 PSI position 2 500 l min 6 bar 132 GPM 87 PSI position 3 FLUSH position 4 Working pressure 16...

Page 8: ...ex A of EN 15182 2 EN 15182 2 Type 3 1 4 Flow rate at PR 500 l min 6 bar 132 GPM 87 PSI 1 5 Flow rate settings 150 250 500 1 6 Type of pattern Hollow cone diffusion 3 1 Coupling system Full time swive...

Page 9: ...2 2 1 Torques needed for moving operating elements N m 2 4 2 2 1 Lever non applicable 2 4 2 2 1 Shutoff handle 8 2 4 2 2 1 Selective flow rate ring 4 5 2 4 2 2 1 Selective flow pattern ring 3 2 4 2 2...

Page 10: ...0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email france pok fr Web www pok fr MOP_LAM_01289_EN Rev A 18 08 2014 Copyright POK SAS Illustrations are only informative 10 Overall dimensions Presentation Weig...

Page 11: ...n total darkness and while wearing firefighting gloves conform to EN 659 This ring also has a position marked PURGE or FLUSH which permits the removal of particles which could interfere with the prope...

Page 12: ...the shutoff from turning If there is not any dismantle the shutoff device as follows Remove the inlet coupling mark 43 and 46 as detailed above Remove the screws mark 5 Remove the ball mark 2 Remove b...

Page 13: ...e gasket mark 23 Clean and grease Locite 8106 grooves and contact aeras of parts mark 22 29 and 34 Insert spring mark 32 and ball mark 33 and reassemble flow rate ring mark 29 Glue Locite 243 and scre...

Page 14: ...nons 10400 Nogent sur Seine FRANCE Tel 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email france pok fr Web www pok fr MOP_LAM_01289_EN Rev A 18 08 2014 Copyright POK SAS Illustrations are only informati...

Page 15: ...160 15 1 Screw CS M5 20 16 1 Nut H M5 17 1 Gasket 55 x 3 18 1 Ball 25 gasket 14768 19 1 Gasket 36 x 4 20 1 Outlet tip 22470 21 1 Screw STHC M5 5 with tip 22 1 Bore cover 22472 23 4 Gasket 45 x 2 24 1...

Page 16: ...Guignons 10400 Nogent sur Seine FRANCE Tel 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email france pok fr Web www pok fr MOP_LAM_01289_EN Rev A 18 08 2014 Copyright POK SAS Illustrations are only infor...

Reviews: