background image

 

Instruction manual/technical specification 

W-647 

5/6 

   

  

 

 

using the jacquard webbing belts and 
self-locking buckles located on the 
segment sides fasten the segments to 
each other,, 

 

 

place the top pad on the landing area 
main segments,, 

          

 

 

 

then fasten the top pad to the main 
segments using D-rings 

 

now the landing area is ready for use. 

V. Operating 

Stepping on the landing area and practising require special footwear designed for those purposes. Treading on the 
landing area in footwear with spikes is only allowed when the landing area is equipped with special spike resistant 
surface. Stepping on the landing areas in hard footwear or in shoes with heels is strongly prohibited. You must not 
put any tables, chairs, benches or any other objects whose unit pressure exceeds 1kg/1cm

2

 on the landing area. If 

the landing area is moved from one place to another very often, it is recommended that a landing area cart should 
be used. 

 
VI. Maintenance  

Due  to  the  hygiene  requirements  it  is  recommended  that  the  landing  area  should  be  cleaned  regularly  with 
commonly  available  detergents.  Before  you  start  wiping  the  landing  area,  please  try  to  clean  a  small  spot  on  its 
bottom side in order to check the reaction with the PVC fabric. 

 
 
VII. Storing 

The landing area segments can be stored only in a horizontal position. They cannot be bent or pressed by any objects 
during  storing.  That  may  deform  the  segments  permanently.  A  storing  facility  should  be  clean  and  dry.  It  ought  to 
provide min. temperature 5º C. 

Summary of Contents for W-647

Page 1: ...L SPECIFICATION INSTRUCTION MANUAL High jump competition landing area W 647 Stands crossbar and platform are available separately File 2016 08 04 Technical Support Paweł Ciechanowski p ciechanowski polanik com ...

Page 2: ...ized sports personnel In no event shall Polanik be liable for any special incidental indirect or consequential damages in connection with the purchase or use of POLANIK products or costs over the original cost of the product Specific warranty terms 1 The use of the landing area outdoors requires a waterproof cover and a landing area platform for proper insulation from the ground Failure to follow ...

Page 3: ...h height m 6 4 0 7 Weight kg 320 kg Number of segments pcs 4 Spike resistant surface Double sided surface element upper and bottom surface of top pad is equipped with spike resistant mesh fabric attached using stainless D rings Segment covering PVC made of polyester with two vinyl layers Internal structure advanced 3 layer construction made of high quality PUR foam Way of segment linking Linking b...

Page 4: ...amages in their internal structures When the landing area elements return to their original dimensions you can place them in high jump field The field surface should be even smooth and without any obstacles If you use the landing area outdoors you should also provide a special waterproof cover P 647 to protect the landing area against unfavourable weather conditions and a modular platform SW 6x4 t...

Page 5: ... heels is strongly prohibited You must not put any tables chairs benches or any other objects whose unit pressure exceeds 1kg 1cm 2 on the landing area If the landing area is moved from one place to another very often it is recommended that a landing area cart should be used VI Maintenance Due to the hygiene requirements it is recommended that the landing area should be cleaned regularly with comm...

Page 6: ...Instruction manual technical specification W 647 6 6 VIII IAAF Certificate ...

Reviews: