6
AU
Telephone Helpline: 1300225960
Fault
Probable Cause
Solution
The appliance
turns on, but the
temperature is too
high/ low
Too much ice on the condenser
Defrost the appliance
Condenser blocked with dust
Call POLAR or qualified technician
Doors are not shut properly
Check doors are shut and seals are not
damaged
Appliance is located near a heat
source, in the direct sunlight or
air flow to the condenser is being
interrupted
Move the refrigerator to a more suitable
location
Ambient temperature is too high
Increase ventilation or move appliance to a
cooler position
Unsuitable foodstuffs are being
stored in the appliance
Remove any excessive hot foodstuffs or
blockages to fan
Appliance is overloaded
Reduce the amount of food stored in the
appliance
Factory default parameters adjusted Call POLAR or qualified technician
The appliance is
leaking water
The appliance is not properly
levelled
Adjust the screw feet to level the appliance
(if applicable)
The appliance is
unusually loud
Loose screw/nut
Check and tighten all nuts and screws
The appliance has not been installed
in a level or stable position
Check installation position and change if
necessary
The display lamp
does not illuminate
Lamp needs replacing
Call POLAR or qualified technician
Light not turned on
Ensure Light button has been pressed
properly
Door does not shut
Dirt/obstacle in runners
Clean runners
Technical Specifications
Model
Voltage
Power
(W)
Current
(A)
Temperature
Range
Capacity
(Litres)
Refrigerant
Dimensions
H x W x D mm
Weight
(kg)
CD229-A
220-240V~
50Hz
160
1.4A
0°C to 12°C
120
R600a (50g)
686 x 696 x
568
57
CD230-A
220-240V~
50Hz
200
1.4A
0°C to 12°C
160
R600a (65g)
686 x 874 x
568
66