Control panel
message/code
Meaning
Required action
RTC
Clock error
Re-set date and time. For details, see “Section
12.1: Service” in the controller manual supplied
with the appliance
CABINET PROBE
Cabinet probe error
• Check that the probe is undamaged
• Check the device-probe connection
• Check the cabinet temperature
• If problem persists, Call POLAR agent or
qualified technician.
EVAPORATOR PROBE
Evaporator probe error
Same as for the cabinet probe error but with
reference to the evaporator probe
CONDENSER PROBE
Condenser probe error
Same as for the cabinet probe error but with
reference to the condenser probe
NEEDLE PROBE
SENSOR 1/2/3
Needle probe/sensor 1/2/3
error
Same as for the cabinet probe error but with
reference to needle probe 1/2/3
NEEDLE PROBE
Needle probe alarm (all
the needle probe sensors
enabled are in alarm
status)
Same as for the cabinet probe error but with
reference to all the needle probes
NEEDLE PROBE
INSERTION
Needle probe not inserted
alarm
Check that the needle probes have been correctly
inserted
DOOR OPEN
Door open alarm
Check the door status
HIGH TEMPERATURE
Maximum temperature
alarm (HACCP alarm)
• Check the cabinet temperature
LOW TEMPERATURE
Minimum temperature
alarm (HACCP alarm)
• Check the cabinet temperature
POWER FAILURE
Power failure alarm (HACCP
alarm)
Check the device-power supply connection
Note: This table just lists very basic alarms. For more detailed alarm information, please
see “Section 16 Alarms” in the controller manual.
Technical Specifications
Model
Voltage
Power
Capacity
Weight
(kg)
Temperature
range
Refrigerant
Dimensions
H x W x D
UA014-A
220-240V~
50Hz
700W
3 x GN1/1
104
+5°C ~ -35°C
R290
965 x 804 x 826
UA015-A
220-240V~
50Hz
720W
5 x GN1/1
116
+5°C ~ -35°C
R290
1035 x 804 x 826
UA016-A
220-240V~
50Hz
900W
10 x GN1/1
150
+5°C ~ -35°C
R290
1885 x 800 x 815