EVCO S.p.A.
Vcolor 869
| Installer manual ver. 1.0 | Code 144VC869E104
page 29 of 92
7.1.1
Combined cycle with slow cooking
When setting a manual blast chilling/freezing cycle, if available in the machine configuration a slow cooking cycle can
be added after a blast chilling/freezing. In the lower part of the screen, two dedicated areas make it possible to add a
slow cooking phase
or a slow c holding phase.
.
For slow cooking or slow c holding the pre-settings are those of the standard cycles.
When setting a manual cycle, the values of each phase can be edited any time.
Below is an example for setting a hard blast c slow c holding.
7.2
Hard blast chilling/soft blast-freezing and conservation
It is possible to select a hard blast chilling/soft blast-freezing cycle on the blast chilling/blast-freezing settings screen
by pressing area
or
. Before selecting this mode, make sure the type of cycle (temperature or time
controlled) has been set.
This cycle consists of two blast chilling phases at different set points, followed by a conservation phase.
-
The first phase, known as hard for blast chilling and soft for blast-freezing, has set points established by
the relevant parameters and these cannot be modified;
-
The set points for the second blast chilling/blast-freezing phase can be modified;
-
The set points for the third conservation phase can be modified.