The defrost output will be activated regardless of the value of parameter d1 for the entire duration of the defrost.
11.11
Thawing heater management
This function is only available if one of the relays is configured as thawing.
These are activated during thawing to bring the cabinet temperature to the set point value. Heaters have a neutral
zone adjustment.
11.12
Proofing and slow cooking heater management
This function is only available if one of the relays is configured as cooking and slow cooking heater
Proofing
When the temperature falls below the neutral zone relative threshold (heating), the heaters will be activated until the
neutral zone temperature is restored. The heaters are activated as ON and OFF cycles given by parameters rH14 and
rH15.
Slow cooking
The heaters are activated to bring the temperature to the set point value.
11.13
Humidifier management
This function is only available if one of the relays is configured as steam injection.
This function is activated on the basis of the humidity percentage set. For example, if this is set at 60%, the output is
activated for 60% of the time set by parameter rU3 and deactivated for the time set by rU2 – rU3. The ON and OFF
humidifying cycle repeats itself until the phase is finished.
11.14
Humidifying/steam
generator
heater
management
This function is only available if one of the relays is configured as steam generator or cabinet heater.
This function is activated at the beginning of a cycle for which humidifying is required and it remains active for the
entire duration of the cycle.
11.15
Cabinet light management
This function is only available if one of the relays is configured as cabinet light.
If present, the light comes on when the door is opened and switches off when it is closed.