EVCO S.p.A.
Vcolor 869
| Installer manual ver. 1.0 | Code 144VC869E104
page 70 of 92
rH4
30
-50
99
°C/°F
(1)
Cabinet temperature set point for proofing phase.
rH5
25
-50
99
°C/°F
(1)
Cabinet temperature set point for holding phase.
rH6
1
0
10
°C/°F
(1)
Neutral zone relative threshold (heating) for all proofing phases.
rH7
120
0
999
Min
Blast chilling phase duration (for proofing cycle).
rH8
240
0
999
Min
Re-awakening phase duration.
rH9
180
0
999
Min
Proofing phase duration.
rH10
80
-50
99
°C/°F
(1)
Cabinet temperature set point for slow cooking.
rH11
60
-50
99
°C/°F
(1)
Product temperature set point for slow cooking.
rH12
60
0
999
Min
Slow cooking duration.
rH13
60
-50
99
°C/°F
(1)
Cabinet temperature set point for holding.
rH14
45
1
600
s
Heater cycle time for proofing.
rH15
4
1
10
s
Heater on time for proofing.
rH16
1
0
10
°C/°F
(1)
Neutral zone relative threshold for thawing.
rH17
2
1
15
°C/°F
(1)
Cabinet set point differential for activating heater during
thawing.
rH18
2
1
15
°C/°F
(1)
Cabinet set point differential for activating compressor during
thawing.
rH19
45
1
600
s
Heater cycle time for thawing.
rH20
4
1
10
s
Heater on time for thawing.
rH21
1
0
10
°C/°F
(1)
Neutral zone threshold for the conservation phase
PAR.
DEFAULT
MIN.
MAX.
U.M.
HUMIDITY REGULATOR
(parameters only valid if E12=1)
rU1
0
-50
99
°C/°F
(1)
Cabinet temperature under which humidifying is inhibited.
rU2
60
1
600
s
Cycle time for switching on humidifier for proofing and slow
cooking.
rU3
30
1
600
s
Humidifier on time within the rU2 cycle time for generating
100% humidity in the cabinet.
rU4
0
0
1
- - - -
Enable humidifying control during blast chilling phase (for
proofing cycle)
0 = no
1 = yes
rU5
60
0
100
%
Pre-set % humidifying for blast chilling (for proofing cycle), if
parameter rU4=1.
rU6
60
0
100
%
Pre-set % humidifying during conservation (retarding proofing
cycle)
rU7
80
0
100
%
Pre-set % humidifying during awakening