F35
5
1
5
- - - -
Fan speed in first sanitation phase (blast chilling).
F36
5
1
5
- - - -
Fan speed in second sanitation phase (holding).
F37
5
1
5
- - - -
Fan speed in third sanitation phase (conservation).
F38
5
1
5
- - - -
Fan speed during customized blast chilling.
F39
5
1
5
- - - -
Fan speed during customized conservation.
F40
5
1
5
- - - -
Fan speed during slow cooking.
F41
5
1
5
- - - -
Fan speed during holding after slow cooking.
F42
5
1
5
- - - -
Fan speed during blast chilling (for proofing cycle)
F43
5
1
5
- - - -
Fan speed during re-awakening.
F44
5
1
5
Fan speed during proofing.
F45
5
1
5
Fan speed during conservation (for proofing cycle)
F46
15
0
99
°C/°F
(1)
Condenser temperature above which the condenser fan switches
on.
F47
30
0
240
s
Condenser fan switch-off delay from when the compressor is
switched off (only if the condenser probe is not present).
F48
---
0
1
0
Condenser fan status during defrosting.
0 = off
1 = on
F49
0
0
1
---
Fan operating mode during conservation
0 = parallel to the compressor
1 = always ON
F50
0
0
1
---
Fan operating mode during slow cooking
0 = always ON
1 = ON if heating elements are ON, with ON-OFF cycles if
heating elements are OFF
F51
180
0
999
s
Fan OFF time during heating when operating with F50 = 1
F52
60
0
999
s
Fan ON time during heating when operating with F50 = 1
F53
1
1
5
---
Minimum fan speed that can be set for all cycles except slow
cooking
NB: check that the value set is consistent with parameters from
F23 to F45
F54
1
1
5
---
Minimum fan speed that can be set for slow cooking
NB: check that the value set is consistent with parameters from
F23 to F45