EVCO S.p.A.
Vcolor 869
| Installer manual ver. 1.0 | Code 144VC869E104
page 77 of 92
u7
40
-50
199
°C/°F
(1)
Temperature to end needle probe heating. See also parameter
u8
u8
2
0
240
min
Maximum duration of needle probe heating. See also
parameter u7
0 = needle probe heating is disabled.
u9
-
-
-
- - - -
unused
u11
0
0
1
- - - -
Enable evaporator ventilation during sterilisation
0=no
1=yes
u12
10
0
999
s
Compressor switch-off delay from deactivation of the pump
down valve (pump down being switched off)
u13
25
1
99
m
Drying duration
PAR.
DEFAULT
MIN.
MAX.
U.M.
COMUNICAZIONE SERIALE (porta seriale di tipo RS-485
con protocollo di comunicazione MODBUS) + EVLINK
WIFI
L1
5
1
240
min
Data recording interval during the main cycles.
The interval is the same both for the internal data-logger and
for EVLINK
LA
247
1
247
- - - -
device address
Lb
3
0
3
- - - -
baud rate
0 = 2,400 Bd
1 = 4,800 Bd
2 = 9,600 Bd
3 = 19,200 Bb
LP
2
0
2
- - - -
parity
0 = none
1 = odd
2 = even
PA1
426
-99
999
- - - -
EVconnect/EPoCA level 1 password
PA2
824
-99
999
- - - -
EVconnect/EPoCA level 2 password
bLE
1
0
99
- - - -
Serial port connectivity configuration
0 = free
1 = forced for EVconnect or EPoCA
2-99 = EPoCA local network address
PAR.
DEFAULT
MIN.
MAX.
U.M.
MISCELLANEOUS
E7
0
0
1
- - - -
Activate “lock keypad” function
0 = function not enabled
1 = automatic with temporary effect (60s time lapse from
the time the key was pressed while a cycle is in
progress, the keypad locks automatically).