11. EFI SYSTEM OF SQR 472ENGINE
11-16
4) Technical parameters
(1) Limit data
value
measure
Least typical
maximum
unit
Working temperature
-40
+125
℃
Stepper motor plug contact the maximum
number of transposon
2.0x10°
time
Characteristic data
value
Least typical
maximum
unit
Resistance of 20
℃
each coil
47.7
53
58.3
Ω
Each coil resistance operating temperature range
35
(
-40
℃
)
95
(
+125
℃
)
Ω
Inductance on 1000Hz 20
℃
each coil
26.8
33.5
40.2
mH
Normal working voltage
7.5
12
V
May the work voltage
3.5
14
V
Stepper motor rotor length
0.04167
nm
The bypass passage is opened at both ends of the
pressure drop
60
kPa
Gas pressure difference caused by the maximum
axial force
6.28
N
5) Installation notes
Idle with stepping motor actuator is installed on the solar term door body castings, constitute a bypass channel at
both ends of the solar term door.
Bolt installation using two M5 0.8 14.
Bolt tightening torque of 4 0.4Nm.
The installation and use of the spring washer, and adhesive.
Idle with stepper motor actuator shaft should not be installed level or lower level, so as to avoid cold Condensate
water into.
Shall not be applied in any form of axial force to axial compression into or out of A.
Before the idle with stepper motor actuator into the solar term door body, the shaft must be fully retracted position
at.
Summary of Contents for 1100 GKE OutLaw
Page 1: ...Service Manual 1100GKE 4 4...
Page 62: ...4 COOLING SYSTEM 4 6 Cooling System Chart...
Page 158: ...10 CVT TRANSMISSION SYSTEM 10 7 5 Appearance installation dimension map Fan shaped array 10...
Page 165: ...11 EFI SYSTEM OF SQR 472ENGINE 11 3 3 The ECU control principle diagram...
Page 166: ...11 EFI SYSTEM OF SQR 472ENGINE 11 4 4 The ECU function module layout...
Page 260: ......