11. EFI SYSTEM OF SQR 472ENGINE
11-31
motor, thereby adjusting flow. So can not be electric fuel pump for vehicle use another type to.
3) Technical parameters
(1) Limit data
value
measure
least typical maximum
unit
working voltage
8
14
V
(
Direct Direct
)
system voltage
380
kPa
Output
voltage
450
650 kPa
The environment temperature (suitable for
storage and transportation)
-40
+80
℃
The license of the fuel temperature
-30
+70
℃
Vibration acceleration license
20
m/s
2) Characteristic data
Electric fuel pump in a fuel pressure flow with voltage proportional to. The oil pump using the car
plant of each are not identical.
Electric fuel pump capacity is 295-305g.
4) Installation notes
Electric fuel pump should be stored in the original packaging box sealed inside. Mounted on the car
after the maximum allowable storage time was 6 months, as accessories maximum storage time for
4 years. Over this time, by the manufacturers to test performance data pump. In the storage place,
must be protected against atmospheric effects of oil pump. During the storage period, the original
packaging shall not be damaged. Electric fuel pump is applied only to the fuel tank. Install the
pump must be installed on the eye size of not more than 60 or agreed with the customer common
inlet strainer. Please pay attention not to make the beam injection holes spewing oil into the oil inlet
filter, oil pump bracket and the oil tank wall. Be careful when handling pump. First of all, we must
protect the oil inlet filter is not affected by the load and impact. Oil pump should be installed to
carefully remove from plastic packaging materials. The protective cover only in the pump
immediately to install to take. Absolutely not allowed to take into the oil strainer. Foreign body into
the oil pump inlet or strainer can lead to pump damage. Install the tubing should pay attention to
clean. Tubing must be clean. Please use the new pipe clamp. Please make sure the hose clamp
The correct position, and follow the method recommended by the manufacturer. Not in the tubing
or in the inlet filter holding pump at. In order to prevent the pump is damaged, please don't run the
pump in the dry state. Do not use damaged pump and once fell to the oil pump on the ground. Oil
fell to the ground, to replace the pump tank. Pressure is not allowed in the oil inlet plate. Caulking
can not have mechanical stress. Pump clamp must be within the scope of the provisions, see below.
Graph: Pump clamping range
If the pump has been used, please rinse with test solution, and dry in the air. Do not allow the oil
pump.
11
Summary of Contents for 1100 GKE OutLaw
Page 1: ...Service Manual 1100GKE 4 4...
Page 62: ...4 COOLING SYSTEM 4 6 Cooling System Chart...
Page 158: ...10 CVT TRANSMISSION SYSTEM 10 7 5 Appearance installation dimension map Fan shaped array 10...
Page 165: ...11 EFI SYSTEM OF SQR 472ENGINE 11 3 3 The ECU control principle diagram...
Page 166: ...11 EFI SYSTEM OF SQR 472ENGINE 11 4 4 The ECU function module layout...
Page 260: ......