4
UK
Installation
Note: If the unit has not been
stored or moved in an upright
position, let it stand upright for
approximately 12 hours before
operation. If in doubt allow to
stand.
1. Remove the appliance from the packaging.
Make sure that all protective plastic film and
coatings are thoroughly removed from all
surfaces.
2. Maintain a distance of 20cm (7 inches)
between the unit and walls or other objects for
ventilation. NEVER LOCATE NEXT TO OR
NEAR A HEAT SOURCE.
Note: Before using the appliance
for the first time, clean the
shelves and interior with soapy
water.
Operation
Control Panel
The control panel is located below the doors on the
rear of the appliance.
Turn On
1. Close the doors of the appliance
2. Connect the appliance to a mains power supply
3. Press the button to turn the light On or Off
as required.
Setting the Operating Temperature
1. Press the SET button. The display will flash
2. Press the
or
buttons to display the
required temperature.
3. Press the SET button to store the temperature
Table of Controller Parameters
The operating parameters of this appliance have been preset for optimum performance and to maximise
the life of the appliance
Display
Parameter
Preset Value
Range
E1
Lower set temperature
2°C
-20°C to 2°C
E2
Upper set temperature
6°C
2°C to 45°C
E3
Temperature buffer
4°C
1°C to 10°C
E4
Temperature buffer time delay
3 minutes
0 to 10 minutes
E5
Fixed parameter
0
DO NOT CHANGE
E6
Fixed parameter
00
DO NOT CHANGE
F1
Defrost period
25 minutes
1 to 60 minutes
F2
Defrost interval
6 hours
1 to 24 hours
F3
Defrost temperature
20°C
0°C to 22°C
F4
Centigrade/Fahrenheit
0°C
°C/°F
CC611-CC666_ML_A5_v6_20180125.indb 4
2018/1/25 17:31