UK
Telephone Helpline: 0845 146 2887 (United Kingdom)
If the temperature measured by the pin probe reaches the chilling endpoint temperature prior to expiry of the
maximum chilling time duration:
the device will switch to storage mode
the display will show the message "End"
the buzzer will sound for the period of time set by parameter AA
press any key to mute the buzzer; press once more to cancel the message "End".
If the temperature measured by the pin probe does not reach the chilling endpoint temperature prior to expiry of
the maximum chilling time duration:
chilling will continue
the LED
will flash and the LED
will be on
the buzzer will sound
press
several times to:
- mute the buzzer
- display the time elapsed since the maximum chilling time expired
- display the cabinet temperature
- display the message "nEg"
- exit the procedure, or leave for 15 seconds
when the temperature measured by the pin probe reaches the chilling endpoint temperature:
- the device will switch to storage mode
- the LED
will continue to flash and the LED
will continue to stay on
- the display will show the message "End"
- the buzzer will sound for the period of time set by parameter AA
- press any key to mute the buzzer; press once more to cancel the message "End".
During storage:
the display shows the cabinet temperature
if chilling had a positive outcome, the LEDs
and
and will be on; if chilling had a negative
outcome, the LEDs
and
will be on and the LED
will flash
the parameter rA sets the operational set point
press
several times to:
- display the message "nEg"
- exit the procedure, or leave for 15 seconds.
To interrupt the cycle:
press
for2 seconds.
Summary of Contents for CK640