To exit the procedure:
• press
and
for 4 s , or leave for 60 s.
Interrupt the device power supply after altering the parameters.
ALARMS
CODE
MESSAGE
AL
Minimum temperature alarm
Remedies:
• check the cabinet temperature
• check parameters A1 and A2
Consequences:
• the device will continue to function normally
AH
Maximum temperature alarm
Remedies:
• check the cabinet temperature
• check parameters A3 and A4
Consequences:
• the device will continue to function normally
id
Micro-port input alarm (only in "stand-by" mode and if parameter i0 is set to 0 or 1)
Remedies:
• check the causes which activated the input
• check parameters i0 and i1
Consequences:
• the outcome set by parameter i0
iA
Compressor protection input alarm (only if parameter i0 is set to 2)
Remedies:
• check the causes which activated the input
• check parameters i0 and i1
Consequences:
• the compressor will be shut down
When the cause that triggered the alarm has been resolved, the device restores normal operation.