background image

2

Telephone Helpline

: 1300225960

Fitting the Shelves

1.

Place one set of shelf guides on either side of the cabinet at the desired height.

2.

Slide the shelf into place.

3.

Repeat for the remaining shelves..

Operation

Storing Food

To get the best results from your POLAR appliance, follow these instructions:

Only store foodstuffs in the appliance when it has reached the correct operating temperature.

Do not place uncovered hot food or liquid inside the appliance.

Wrap or cover food where possible.

Do not obstruct the fans inside the appliance.

Avoid opening the doors for prolonged periods of time.

Turn On

1.

Close the door(s) of the appliance.

2.

Ensure the power switch is set to [O] and turn on at the socket.

3.

Switch on the Power [I]. The current temperature within the appliance is displayed.

Control Panel

To See the Setpoint

Push and immediately relese the SET key: the display will show the Setpoint value

Changing the Setpoint

1) Push the SET key for more than 2 seconds to change the Setpoint value
2) The value of the set point will be displayed and the COMPRESSOR LED starts 
blinking
3) To change the Set value push the UP and DOWN buttons within 10 seconds
4) To store the new Setpoint push the SET key or wait 10 seconds

Manual Defrost

The appliance will automatically run a defrost cycle every six hours. 

To manually defrost the appliance:

1.

Press and hold the aux button for more then 2 seconds.

2.

The defrost cycle will start immediately and the Defrost LED illuminates. .

3.

The next automatic defrost will start six hours after the manual defrost has finished.

Note: The cycle starts from the time the appliance is initially powered up.

Note: Starting a manual defrost also resets the automatic defrost timer. 

Summary of Contents for DL893-A

Page 1: ...Model DL893 A DL894 A DL895 A DL896 A DL897 A DL898 A DL899 A CK480 A Cabinet Refrigerators Freezers Instruction manual ...

Page 2: ...White Freezer Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product Pack Contents The following is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should y...

Page 3: ...within the appliance is displayed Control Panel To See the Setpoint Push and immediately relese the SET key the display will show the Setpoint value Changing the Setpoint 1 Push the SET key for more than 2 seconds to change the Setpoint value 2 The value of the set point will be displayed and the COMPRESSOR LED starts blinking 3 To change the Set value push the UP and DOWN buttons within 10 second...

Page 4: ...ive Scourers or scrubbing pads etc Use Chlorinated or acidic detergents Allow anything e g food dirt cleaning chemicals to remain on the surface for longer than necessary clean them off right away Allow the surface to remain wet Do Clean often Use soft Cloths or plastic Scourers Rub with the grain of the metal rather than across it Use detergents and polish designed for cleaning Stainless Steel En...

Page 5: ...erature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being stored in the appliance Remove any excessive hot foodstuffs or blockages to the fan Appliance is overloaded Reduce the amount of food stored in the appliance The appliance is leaking water The appliance is not properly levelled Adjust the screw feet to level the appliance if applicable T...

Page 6: ...environment the product must be disposed of in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in your area POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international...

Page 7: ...k AS NZ 3820 Essential Safety Requirements for Low Voltage Electrical Equipment Standards EN 55014 1 2006 EN 55014 2 1997 A1 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 A2 EN 61000 3 11 2000 EN 55015 2006 EN 61547 1995 A1 AS NZS 60335 2 89 2002 A1 2003 A2 2005 A3 2007 with AS NZS 60335 1 2002 A1 2004 A2 2007 A3 2007 Producer Name POLAR Producer Address 15 Badgally Road Campbelltown NSW 2560 Date 24 03 ...

Page 8: ...DL893 A_DL899 A_A4_v6 ...

Reviews: