2
UK
Fitting the Shelves
1. Place one set of shelf guides on either side of the cabinet at the desired
height.
2. Slide the shelf into place.
3. Repeat for the remaining shelves.
Operation
Storing Food
To get the best results from your POLAR appliance, follow these instructions:
•
Only store foodstuffs in the appliance when it has reached the correct
operating temperature.
•
Do not place uncovered hot food or liquid inside the appliance.
•
Wrap or cover food where possible.
•
Do not obstruct the fans inside the appliance.
•
Avoid opening the doors for prolonged periods of time.
Turn On
1. Close the door(s) of the appliance.
2. Ensure the power switch is set to [O] and turn on at the socket.
3. Switch on the Power [I]. The current temperature within the appliance
is displayed.
Control Panel
Lock/Unlock the Control Panel
To lock the control panel:
1. Press and hold the UP
and DOWN
buttons simultaneously for 10
seconds.
2.
Pof
flashes on the display and the keyboard is locked.
To unlock the control panel:
1. Press and hold the UP
and DOWN
buttons simultaneously for 10
seconds.
2.
Pon
flashes on the display and the keyboard is unlocked.
Enter the Parameter Menu
1. Unlock the control panel, if locked.
2. Press and hold the SET
button until ‘
d1
’ flashes on the display.
3. Press the SET
button repeatedly to scroll to the desired parameter
(see below).
.
Note: Always place one shelf in the lowest available position,
or if that position is higher than 40mm, place the shelf
directly onto the floor of the cabinet without the guides.
This is vital for ensuring correct drainage of condensation.
Note:
If a button is not pressed for 10 seconds while using the
control panel it times out and reverts to standby mode.
When parameters are being set the Setpoint LED will flash on
the display.
Pon
Parameter
Name
Description
Range
d1
Operating temperature
Set the operating temperature of the appliance
-2°C to 10°C
d2
Temperature
Differential
The Temperature Differential is the allowed temperature difference above and below the
operating temperature before the compressor starts/cuts off
0 to 20°C
d3
Temperature Range
Set the minimum (d3) and maximum (d4) temperatures that the appliance can fluctuate
between
-40°C
d4
95°C
d5
Compressor Activation
Time Intervals
Enter the minimum time interval between the compressor turning off after turning on.
0-999 seconds
d6
Maximum Temperature
Differential Alarm
Set an alarm to sound if the temperature inside the appliance exceeds the set operating
temperature by a specified amount
0°C-50°C
d7
Temperature
Differential Alarm Delay
Set a delay before the temperature differential alarm is triggered
0-99 minutes
d8
Defrost Cycle Time
Intervals
Set the time between each defrost cycle
1-999 hours
d9
Maximum Defrost
Duration
Set the maximum length of the defrost cycle
Note: The defrost duration can be overridden by parameter d10 (below), if the
cut-off temperature is reached before the end of the defrost duration
0-999 minutes
d10
Defrost Cut-off
Temperature
(G591/G593/G595 only)
Set the defrost cut-off temperature
-45°C to 50°C
d11
Additional Cut-off
Defrost Period
(G591/G593/G595 only)
Set an additional amount of defrost time after the defrost cut-off
point has been reached (if required)
0-99 minutes
d12
Delayed Actual
Temperature Display
Set the length of time the inner temperature of the appliance (before defrost started) is
displayed for after a defrost cycle has finished
0-99 minutes
d13
Compressor On/Off
During Defrost
(G591/G593/G595 only)
Turn the Compressor On or Off during the defrost cycle
On (
1
) or Off (
0
)
d14
Evaporator Drying Time
Set the amount of time the compressor remains turned Off after a defrost cycle, reducing the
amount of frost build up
0-99 minutes