background image

3

UK

Manual Defrost

The appliance will automatically run a defrost cycle every six hours. 

To manually defrost the appliance:

1. Press and hold the DEFROST 

 button for 5 seconds.

2. The defrost cycle will start immediately and the Defrost LED illuminates. 

The defrost will last a maximum of 30 minutes.

3. Waste water is collected in the waste water tray.

Lock/Unlock the Doors

A lock is fitted to the doors to ensure foodstuffs are kept secure within your 
POLAR appliance.
Use the keys provided to lock/unlock the doors.

Cleaning, Care & Maintenance

Switch off and disconnect from the power supply before cleaning.

Clean the interior of the appliance as often as possible.

Do not use abrasive cleaning agents. These can leave harmful residues. 

Clean the door seal with water only.

Always wipe dry after cleaning.

Do not allow water used in cleaning to run through the drain hole into 
the evaporation pan.

Take care when cleaning the rear of the appliance. Sharp edges can cut. 

A POLAR agent or qualified technician must carry out repairs if required.

Cleaning the Condenser

Periodically cleaning the condenser can extend the life of the appliance.
POLAR recommend that a POLAR agent or qualified technician clean the 
condenser.

Troubleshooting

If your POLAR appliance develops a fault, please check the following table 
before making a call to the Helpline.

Parameter

Name

Description

Range

=

19

Temperature Offset

Should there be any variance between measured and actual temperature, the measured 

temperature can be offset to compensate

-20°C to 20°C

=

22

Unit of Measurement

Set whether the temperature is displayed in Centigrade or Fahrenheit

Centigrade (

0

) or Fahrenheit (

1

)

=

23

Compressor Operation 

During Probe Failure

Set whether the compressor runs or remains Off during a temperature probe failure

Compressor runs (

1

)

Remains Off until fault fixed (

0

Runs intermittently with 

parameters =

24

 and =

25 

(

2

=

24

Compressor ‘On’ 

Duration

Set the length of time the compressor runs during a temperature probe failure

1-99 minutes

=

25

Compressor ‘Off’ 

Duration

Set the length of time the compressor remains Off during a temperature probe failure

1-99 minutes

=

34

Initial Defrost After 

Startup 

(G591/G593/G595 only) 

Set whether the appliance starts a defrost cycle 10 minutes after 

startup or after the time programmed in parameter 

d8

 (Defrost Cycle Time Intervals)

Begins 10 minutes after startup 

(

0

) or when programmed (

1

)

=

38

Minimum Temperature 

Alarm

Set the display to flash should the inner temperature of the appliance drop beyond a specified 

point from the programmed operating temperature

1°C to 50°C

Note: The cycle starts from the time the appliance is initially 
powered up.

Note: Starting a manual defrost also resets the automatic 
defrost timer. 
The next automatic defrost will start six hours after the 
manual defrost has finished.

Fault

Probable Cause

Action

The appliance 

is not working

The unit is not switched on

Check the unit is 

plugged in correctly 

and switched on

Plug and lead are damaged

Call POLAR agent or 

qualified Technician

Fuse in the plug has blown

Replace the fuse

Power supply

Check power supply

Internal wiring fault

Call POLAR agent or 

qualified Technician

The appliance 

turns on, but 

the 

temperature is 

too high/low

Too much ice on the condenser

Defrost the appliance

Condenser blocked with dust

Call POLAR agent or 

qualified Technician

Doors are not shut properly

Check doors are shut 

and seals are not 

damaged

Appliance is located near a heat 

source or air flow to the 

condenser is being interrupted

Move the refrigerator to 
a more suitable location

Ambient temperature is too 

high

Increase ventilation or 

move appliance to a 

cooler position

Unsuitable foodstuffs are being 

stored in the appliance

Remove any excessive 

hot foodstuffs or 

blockages to the fan

Appliance is overloaded

Reduce the amount of 

food stored in the 

appliance

The appliance 

is leaking water

The appliance is not properly 

levelled

Adjust the screw feet to 

level the appliance

The discharge outlet is blocked

Clear the discharge 

outlet 

Movement of water to the drain 

is obstructed

Clear the floor of the 

appliance

The water container is 

damaged

Call POLAR agent or 

qualified Technician

The drip tray is overflowing

Empty the drip tray

The appliance 

is unusually 

loud

The frame has become loose

Check and tighten all 

nuts and screws

The appliance has not been 

installed in a level or stable 

position

Check installation 

position and change if 

necessary

Summary of Contents for G590

Page 1: ...Stainless Steel Cabinet Refrigerators Freezers Models G590 G591 G592 G593 G594 G595 U629 U630 ...

Page 2: ...only 1 Fitting the Waste Water Tray G592 G593 G594 G595 U629 U630 only 1 Fitting the Shelves 2 Operation 2 Storing Food 2 Turn On 2 Control Panel 2 Lock Unlock the Control Panel 2 Enter the Parameter Menu 2 Manual Defrost 3 Lock Unlock the Doors 3 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Compliance 4 ...

Page 3: ...eration of this machine will provide the best possible performance from your POLAR product Pack Contents The following is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your POLAR dealer immediately Installation 1 Remove the appl...

Page 4: ...e display Pon Parameter Name Description Range d1 Operating temperature Set the operating temperature of the appliance 2 C to 10 C d2 Temperature Differential The Temperature Differential is the allowed temperature difference above and below the operating temperature before the compressor starts cuts off 0 to 20 C d3 Temperature Range Set the minimum d3 and maximum d4 temperatures that the applian...

Page 5: ...1 99 minutes 34 Initial Defrost After Startup G591 G593 G595 only Set whether the appliance starts a defrost cycle 10 minutes after startup or after the time programmed in parameter d8 Defrost Cycle Time Intervals Begins 10 minutes after startup 0 or when programmed 1 38 Minimum Temperature Alarm Set the display to flash should the inner temperature of the appliance drop beyond a specified point f...

Page 6: ...e Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician LtA The inner temperature exceeds the set minimum temperature Display flashes Alternating error message and current temperature Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician PF1 Short circuit or interruption of the thermostat probe input line Display flashes Compres...

Page 7: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...

Reviews: