Stainless Steel Counter Refrigerators/Freezers

Models: 

G596/G597/G598/G599/G600/G601/G621/G622/U636/U637/U638

Summary of Contents for G596

Page 1: ...Stainless Steel Counter Refrigerators Freezers Models G596 G597 G598 G599 G600 G601 G621 G622 U636 U637 U638 ...

Page 2: ... 1 Fitting the Shelves Floor Guards 1 Operation 1 Storing Food 1 Turn On 1 Control Panel 1 Lock Unlock the Control Panel 1 Enter the Parameter Menu 2 Manual Defrost 2 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Disposal 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Compliance 4 ...

Page 3: ...ng is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your POLAR dealer immediately Installation 1 Remove the appliance from the packaging Make sure that all protective plastic film and coatings are thoroughly removed from all sur...

Page 4: ...e The defrost duration can be overridden by parameter d10 below if the cut off temperature is reached before the end of the defrost duration 0 999 minutes d10 Defrost Cut off Temperature Set the defrost cut off temperature 45 C to 50 C d11 Additional Cut off Defrost Period Set an additional amount of defrost time after the defrost cut off point has been reached if required 0 99 minutes d12 Delayed...

Page 5: ...ot working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperature is too high low Too much ice on the condenser Defrost the...

Page 6: ...erature exceeds the set minimum temperature Display flashes Alternating error message and current temperature Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician PF1 Short circuit or interruption of the thermostat probe input line Display flashes Compressor operates as specified by parameter 23 PF2 Short circuit or interruption of the evaporator probe input lin...

Page 7: ...Notes ...

Page 8: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...