background image

© 2019 Polara Engineering, Inc.    Doc. 350-058-01   Rev. C-25059  12/4/2018    Page 2 of 2

www.polara.com

2.  iPHCU3W

Note:  Removing power from the pedestrian signal head during installation is 

recommended for protection from electric shock.

2.1 The iPHCU3W normally installs inside the Pedestrian Signal Head (PED 

Head). It is supplied with a hardware kit which includes a mounting plate and 

associated screws and nuts. The photo (next page) shows an example of a 

typical installation. Typically, tapped ¼-20 holes are present. If they are not, 

a hole (or holes) to match the mounting plate need to be drilled and tapped. 

While a single screw is sufficient to secure the iPHCU3W bracket to the PED 

Head, a second screw may be used for additional stability. Distance between 

holes should be 9.3”.
2.1.1  Attach the iPHCU3W to the mounting plate with the supplied 6-32 

hardware. Insert the 6-32 screws from the back of the assembly 

and secure with the 6-32 nuts. The nuts should be on the top of the 

assembly.

2.1.2  Fasten the assembly to the ped head with the 1/4-20 screws.

2.2 Install jumper wires to connect the light power terminal block to the 

iPHCU3W input power terminal block. Install jumper wires for AC Neutral, 

Walk, and Don’t Walk.

2.3 Connect the wires from previously installed 3-wire cable to the output terminal block of the iPHCU3W.

3.  Technical Support Contact

Polara @ 714-521-0900 or 888-340-4872

The latest version of the complete manual is available in PDF format at www.polara.com.

To PED Call 

Inputs, if available

Ped Head Light Power  Terminal 

Block

WALK

 

DON’T WALK

iPHCU3W

iN3 PBS

 

AC NEUTRAL

EARTH GND,

if available

2.1

Reviews: