Preliminary wiring system
Mains supply
To mount the gate drive, it is necessary to do as follows:
• Connect the power of 230 V to one of the posts, as close to the drive as possible.
• Bring the posts together with a conductor 2 x 1 mm2 (not included in the delivery).
Before, you need to buy a distribution box of IP55 to protect the connection between the conductor going
from the drive and the extension going to the control module. You need also the shield Orange ICT 0 25 mm
for underground conductors.
If conductors cannot be led underground between the posts, use a cable bush that will withstand vehicle
weights.
23
1
Poprzeczka
Moduł
elektroniczny
Skrzynka
połączeniowa
(nie dostarczana
w zestawie)
przewód 2 x 1 mm² między napędami
przewód 2 x 0,75 mm² między fotokomórkami
2
3
Giętka osłona ICT
(
)
Power connection: conductors 3 x 1.5 mm
2
for external use
Connection of 24 V between two drives: (2 x 1 mm
2
)
To ensure operation of the gate opening mechanism, the supply of 230 V - 50 Hz shall be connected to it.
The electric line must be:
•
Designed only for the gate opening mechanism.
•
Protected:
– by means of a fuse or a trip of 10 A,
- by means of a residual-current device (30 mA).
•
Mounted according to safety standards for electric systems that are valid in the country of use.
Provide a possibility of multipole disconnection of the power supply:
•
using a power cable with a plug,
•
or by means of a switch that allows maintenance of a minimum distance of 3 mm between
contacts, at each pole (according to EN 60335-1).
It is recommended to install a lightning arrester (maximum residual voltage of 2 kV).
1
2
Widok od
strony
posesji
Preparation for assembly
View from the
estate side
Junction box (not
included in the
delivery)
Electronic module
Crosspiece
Flexible shield ICT
( )
conductor 2 x 1 mm
2
between drives
conductor 2 x 0.75 mm
2
between photocells
12
EN
- Assembly and service manual for EASY WAY202
EN
Use of conductors of smaller cross-sections than shown in the manual can result in voltage drops
that can cause improper motor operation.