Risk prevention
▶
Dangerous zone determination
▶
Batteries
▶
Worn out equipment recycling and disposal
▶
Regulatory compliance
WARNING
Monthly, check as follows:
- installation, to detect any signs of wear and tear or damage of conductors or assembly components,
- if the power unit changes direction of its operation when the gate encounters an obstacle of 50 mm that can be
found mid-height of the gate leaf.
Do not use the power unit that requires repair or adjustment. The gates in a bad technical condition shall be
repaired, strengthened or even replaced.
Use only original parts for servicing and repair.
Introduction of any technical, electronic or mechanical modifications within the power unit requires consent of the
POLARGOS Technical Assistance Department.
If the system is equipped with photocells and/or the orange light, clean optic elements of the photocells and the
orange lamp regularly.
DANGER
Do not leave batteries / tablet batteries / rechargeable batteries within reach of children. They shall be stored out
of reach of children. There is a hazard that children or pet animals can swallow these elements. Danger of death!
Nevertheless, if such situation occurs, consult a doctor immediately or go to hospital.
Be careful to avoid battery short circuit. Do not throw batteries into fire or recharge them. Risk of explosion occurs.
Hereby, POLARGOS declares that the product described in this manual, if it is used according to the given
recommendations, conforms to the basic requirements of European Directives in force and, in particular, the
Machinery Directive 2006/42/EC and Radio Equipment Directive 2014/53/EU.
The full text of the Declaration of Conformity is available at: www.somfy.com/ce. Antoine CREZE, Regulatory Compliance
Manager, Cluses.
Remove a rechargeable battery (if any) from the power unit before its transfer for disposal.
Do not discard the worn out remote control batteries or a rechargeable battery (if any) together with household
waste. Transfer them to a special waste collection point for recycling.
Do not discard the out of use power unit together with household waste. Such a power unit shall be transferred to its
distributor or to a selective waste collection point made available by the municipality authorities.
Safety rules
Zone 1
Zone 2
Zone 2
Zone 4
Zone 4
Zone 3
Zone 3
Zone 5
Zone 5
Zone 2
Zone 2
Zone 4
Zone 4
Zone 1
Zone 3
Zone 3
6
EN
- Assembly and service manual for EASY WAY202
EN