31
EN
SOLAR ENERGY SUPPLY
►
Connection to a solar energy source
►
Advice concerning use
Connect the lead-in wire from a solar battery
to the grey terminal „BATT” of the electronic module
of the drive.
When the drive unit operates using a solar energy supply:
- the gate can be controlled by means of remote controls and radio transmitters only (wire control is inactive),
- protecting wire accessories (photocells, the orange light) are still active.
Note:
When the drive is supplied with a solar energy
source, the wire control systems are disconnected; the
gate is controlled by means of remote controls and radio
transmitters only.
+
-
1
2
3
Never connect the drive unit to a power supply of 230 V when it is already
connected to a solar energy source because this can lead to damage to the
electronic module of the drive.
To reduce energy consumption by the gate drive unit,
we recommend the following:
- the gate should stay closed to ensure a longer period
for battery recharging,
- the gate should not remain open for longer than 2 days,
- switch on automatic closing mode of the system
(see page 21).