17
DIP SWITCHES
DIP SWITCHES
* - Default factory setting
DIP Switch 1 – Left or Right Hand Operation
ON – Left hand operation
OFF* - Right hand operation
NOTE: When standing on the inside of the property
looking out, if the gate operator is on your right, then it
is a “right hand operation.”
DIP Switch 2 – Auto Close
ON – Auto close feature enabled
OFF* - Auto close feature disabled
DIP Switch 3 – Audible Motion Alarm
ON – Audible motion alarm enabled
OFF* - Audible motion alarm disabled
DIP Switch 4 – Primary or Secondary Gate Operation
ON – Secondary
OFF* – Primary
NOTE: When DIP Switch 4 is ON, all command inputs
for that operator are disabled. Included are the OPERATE
GATE button, remote input, loop detector, etc.
DIP Switch 5 – Fail Safe or Fail Secure Operation
ON – Fail Secure
OFF* - Fail Safe
DIP Switch 6 – Capability to Manually Move Gate
ON – Ability to move gate manually is disabled
OFF* – Ability to move gate manually is enabled
DIP Switch 7 – Constant or Momentary Pressure
ON – Constant pressure required to operate gate
OFF* – Momentary contact required to operate gate
DIP Switch 8 – Not Used
Figure 16
NOTE: All DIP switches are
shown in the factory default
position (OFF).
Summary of Contents for SL2000