background image

PRODUCT SPECIFICATIONS

Par

t Number

GP

M (LP

M)

Ra

ted Lif

e

(hrs)

Lamp W

atts

Voltage at 50/60H

z

Visual W

ar

ning

Audible W

ar

ning

# of Lamps

Por

t Siz

e

I/O

Wa

te

r

Chamber

Timer

Length

W

idth

M

ax.

Pr

essur

e

W

or

king

Temp

.

W

av

elength

M

icr

ojoules

UVA-1C

1

(3.8)

9,000 10W

110V/220V

LED

BUZZER

1

1/4” MNPT

STAINLESS 

304

-

10.47”

2”

125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-2C

2

(7.57)

9,000 14W

110V/220V

LED

BUZZER

1

1/4” MNPT

STAINLESS 

304

-

13.74” 2.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-4C

4

(15.14)

9,000 17W

110V/220V

LED

BUZZER

1

1/2” MNPT

STAINLESS 

304

-

15.50” 2.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-6C

6

(22.71)

9,000 24W

110V/220V

LED

INDICATOR 

w/ALARM

1

1/2” MNPT

STAINLESS 

304

-

23.23” 2.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-8C 

8

(30.28)

9,000 32W

110V/220V

LED

INDICATOR 

w/ALARM

1

3/4” MNPT

STAINLESS 

304

-

27.87” 2.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-12C

12

(45.52)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

1

3/4” MNPT

STAINLESS 

304

-

36.81” 2.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-24B

24

(90.85)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

2

1” MNPT

STAINLESS 

304

36.93” 3.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-36B 

36

(136.27)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

3

1.5” MNPT

STAINLESS 

304

36.93” 5.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-50B

50

(189.27)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

4

1.5” MNPT

STAINLESS 

304

36.93” 5.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-60B

60

(227.12)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

5

2” OR 2.5”

FLANGE

STAINLESS 

304

36.93” 5.5” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-80B

80

(302.83)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

6

2” OR 2.5”

FLANGE

STAINLESS 

304

36.93” 6.26” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-100B

100

(378.54)

9,000 39W

110V/220V

LED

INDICATOR 

w/ALARM

8

2” OR 2.5”

FLANGE

STAINLESS 

304

36.93” 8.62” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-150B

150

( 567.81)

9,000 87W

110V/220V

LED

INDICATOR 

w/ALARM

6

3”

FLANGE

STAINLESS 

304

36.93” 8.62” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

UVA-200B

200

( 757.08)

9,000 87W

110V/220V

LED

INDICATOR 

w/ALARM

8

4”

FLANGE

STAINLESS 

304

36.93” 8.62” 125 PSI 35

o

F - 104

o

F

(1.67

o

C - 40

o

C)

254 nm

30 mJ/cm

2

DISTRIBUTED BY:

UV Performance

Polaris Scientific Ultraviolet

TM

 Sterilization Systems

 germicidal lamps are specially designed 

Ultraviolet radiation lamps which produce a rated wavelength of 254nm. Ultraviolet radiation 
in the 200-300 nm range is very effective in killing microorganisms such as bacteria, virus, 
mold and yeast.

Polaris Scientific Ultraviolet

TM

 Sterilization Systems

 are ideal for use in drinking water, waste 

water and ground water remediation. They are also ideal for bottling plants, pharmaceutical 
applications, semiconductor sterilization and the food industry.

Polaris Scientific Ultraviolet

TM

 Sterilization Systems

 utilize a natural quartz sleeve to protect 

the lamp and allow the maximum amount of UV rays to penetrate and disinfect the water.

Polaris Scientific Ultraviolet

TM

 Sterilization Systems

 are your best choice in Ultraviolet 

Sterilization. With their durable construction, high quality quartz sleeve and  performance 
lamps you simply can’t go wrong!

R

R

oH

oH

S

S

C

C

O

O

M

M

PL

PL

I

I

AN

AN

T

T

Your 

best 

choice in Ultraviolet Sterilization

For models: 

UVA-1C, UVA-2C, UVA-4C, UVA-6C, UVA-8C, UVA-12C, UVA-24B – UVA-200B

Ultraviolet Sterilization System

Installation Instructions 

& Owner’s Manual

LIT-PSUVA-M_5/9/16

P.O. Box 2235 Chino Hills, CA 91709 • USA

Summary of Contents for UVA-12C

Page 1: ... 302 83 9 000 39W 110V 220V LED INDICATOR w ALARM 6 2 OR 2 5 FLANGE STAINLESS 304 36 93 6 26 125 PSI 35o F 104o F 1 67o C 40o C 254 nm 30 mJ cm2 UVA 100B 100 378 54 9 000 39W 110V 220V LED INDICATOR w ALARM 8 2 OR 2 5 FLANGE STAINLESS 304 36 93 8 62 125 PSI 35o F 104o F 1 67o C 40o C 254 nm 30 mJ cm2 UVA 150B 150 567 81 9 000 87W 110V 220V LED INDICATOR w ALARM 6 3 FLANGE STAINLESS 304 36 93 8 62 ...

Page 2: ...AGILE LEGEND UVA 8C UVA 24B UV PLUG Plastic Plug for Nuts for Models UVA 6C UVA 200B UV 32SPRING Stainless Steel Spring for Model UVA 8C UV TIMER Counter Timer for Models UVA 24B UVA 200B UV 39SPRING Stainless Steel Spring for Models UVA 12C UVA 200B BEB 1024 Ballast for 10W 17W 110V 220V for Models UVA 1C UVA 4C BEB 2439 Ballast for 24W 39W 110V 220V for Models UVA 6C UVA 12C UV SEAL Seal for Sle...

Page 3: ... at an effective life of approximately 9000 hours To ensure continuous protection replace the UV lamp annually Polaris Scientific UltravioletTM warrants the ultraviolet disinfection system s hardware and electrical systems to be free from defects in material and workmanship for a period of five 5 years from the date of purchase by the original owner on a pro rated basis Polaris Scientific Ultravio...

Page 4: ...e UV lamp The connector is keyed and will only allow correct installation in one position Ensure the connector is fully seated onto the UV lamp 3 Once the lamp is fully seated on the connector slide the connector over the aluminum retaining nut Make sure the metal retaining ring on the connector is pulled away from the body of the connector in order that the connector may slide fully over the reta...

Page 5: ...e gland nuts hand tight is sufficient h Re tighten all connections turn on water and check for leaks i Re install the UV lamp and lamp connector as per prior instructions j Reconnect system to power source Note If the system is put on a temporary by pass or if it becomes contaminated after the disinfection system itwillbenecessarytoshockthesystemwithhouseholdbleachforafull20minutesbeforeresumingus...

Page 6: ...In case of a leak shut water off drain cell remove the retainer nut wipe the O ring and threads clean and re install 4 Once it is determined that there are no leaks very carefully slide the UV lamp into the UV chamber making sure the lamp pins are accessible for connection with the lamp connector cable Attach the lamp connector to the UV lamp as outlined in UV Lamp Replacement on page 5 Plug the d...

Page 7: ...In case of a leak shut water off drain cell remove the retainer nut wipe the O ring and threads clean and re install 4 Once it is determined that there are no leaks very carefully slide the UV lamp into the UV chamber making sure the lamp pins are accessible for connection with the lamp connector cable Attach the lamp connector to the UV lamp as outlined in UV Lamp Replacement on page 5 Plug the d...

Page 8: ...e gland nuts hand tight is sufficient h Re tighten all connections turn on water and check for leaks i Re install the UV lamp and lamp connector as per prior instructions j Reconnect system to power source Note If the system is put on a temporary by pass or if it becomes contaminated after the disinfection system itwillbenecessarytoshockthesystemwithhouseholdbleachforafull20minutesbeforeresumingus...

Page 9: ...e UV lamp The connector is keyed and will only allow correct installation in one position Ensure the connector is fully seated onto the UV lamp 3 Once the lamp is fully seated on the connector slide the connector over the aluminum retaining nut Make sure the metal retaining ring on the connector is pulled away from the body of the connector in order that the connector may slide fully over the reta...

Page 10: ... at an effective life of approximately 9000 hours To ensure continuous protection replace the UV lamp annually Polaris Scientific UltravioletTM warrants the ultraviolet disinfection system s hardware and electrical systems to be free from defects in material and workmanship for a period of five 5 years from the date of purchase by the original owner on a pro rated basis Polaris Scientific Ultravio...

Page 11: ...AGILE LEGEND UVA 8C UVA 24B UV PLUG Plastic Plug for Nuts for Models UVA 6C UVA 200B UV 32SPRING Stainless Steel Spring for Model UVA 8C UV TIMER Counter Timer for Models UVA 24B UVA 200B UV 39SPRING Stainless Steel Spring for Models UVA 12C UVA 200B BEB 1024 Ballast for 10W 17W 110V 220V for Models UVA 1C UVA 4C BEB 2439 Ballast for 24W 39W 110V 220V for Models UVA 6C UVA 12C UV SEAL Seal for Sle...

Page 12: ... 302 83 9 000 39W 110V 220V LED INDICATOR w ALARM 6 2 OR 2 5 FLANGE STAINLESS 304 36 93 6 26 125 PSI 35o F 104o F 1 67o C 40o C 254 nm 30 mJ cm2 UVA 100B 100 378 54 9 000 39W 110V 220V LED INDICATOR w ALARM 8 2 OR 2 5 FLANGE STAINLESS 304 36 93 8 62 125 PSI 35o F 104o F 1 67o C 40o C 254 nm 30 mJ cm2 UVA 150B 150 567 81 9 000 87W 110V 220V LED INDICATOR w ALARM 6 3 FLANGE STAINLESS 304 36 93 8 62 ...

Reviews: