Instr 9929139
Rev 01 2018-08
Page 7 of 13
f.
Connect the red positive (+) and black negative
(–) power cables to the corresponding positive
(+) and negative (–) terminals on the pulse bar
or busbar.
MY 19
and newer vehicle use the provided
cable connection nuts
j
to secure the power
cables in place as shown below. Torque to
specification provided.
TORQUE
24 in. lbs. (2.8 Nm)
MY18
and older you will need to route and
secure the red positive (+) and black negative
(–) power cables with the existing cable
connection nuts to the corresponding positive
(+) and negative (–) busbar terminals as shown
in the image below. Torque all nuts to
specification provided.
TORQUE
36 in. lbs. (4.1 Nm)
g. Ensure all wires are secured in place away
from all moving parts, sharp edges and heat
sources with provided cable ties.
9.
CONNECT BATTERY.
WARNING
When BOTH battery cables are disconnected
ALWAYS
reconnect AND tighten red positive (+)
cable to battery
FIRST
. Failure to do so will result in
a high current electrical arc, and may result in battery
explosion, if tool touches grounded frame. Death or
serious personal injury may occur.
a. Reinstall red positive (+) cable to positive (+)
battery terminal.
b. Reinstall black negative (–) cable to negative
(–) battery terminal.
c. Reinstall battery access panel
C
.