48
FEATURES
Instrument Cluster
Rider Information Center
Diagnostic Display Code Definitions
Open Load:
There is a break in the wires that lead to the item listed in
the chart (injector, fuel pump, etc.), or the item has failed.
Short-to-Ground:
The wire is shorted to ground between the electronic
control unit and the item listed in the chart.
Shorted Load:
The wires leading to the item listed in the chart are
shorted together, or the item has shorted internally.
Short-to-Battery:
The wire leading from the item listed in the chart to
the electronic control unit is shorted to a wire at battery voltage.
Diagnostic Codes
Component
Condition
SPN
FMI
Throttle Position Sensor
Voltage Too High
51
3
Voltage Too Low
4
Abnormal Rate of Change
10
Vehicle Speed Sensor
Data Erratic, Intermittent or Missing
84
2
Intake Air Temperature Sensor
Voltage Too High
105
3
Voltage Too Low
4
Barometric Pressure Sensor
Voltage Too High
108
3
Voltage Too Low
4
Engine Temperature Sensor
Voltage Too High
110
3
Voltage Too Low
4
Temperature Too High
16
Engine Overheat Shutdown
0
Temperature Above Normal Range
15
Alternator Power Supply
Potential (DC Chassis Voltage)
Voltage Too High
167
3
Voltage Too Low
4
Exhaust Temperature Sensor
Voltage Too High
173
3
Voltage Too Low
4