Page 8
English
4.1 The Polaris P825 Cleaner Control Unit
4.2 Submerging the Cleaner
1.
Submerge the cleaner vertically (1) and hold it
under the surface, moving gently from side to
side (2) until the bubbles stop to remove any
air trapped inside (see Figure 12).
2.
When the bubbles stop, allow the cleaner to
sink to the bottom of the pool.
3.
Verify the cleaner is sitting on the bottom
of the pool. Remove additional air if the
cleaner is still floating.
NOTE:
The cable side of the cleaner remains up as long as
the pump is OFF. As soon as you turn the pump ON,
the handle lowers.
SURFACE CONTROL SYSTEM
1
2
3
4
ROUGH
SMOOTH
Select Cleaning Surface
• Floor
• Floor and Walls
Start/Stop
Cleaner
Cleaner Error
Indicator
Surface Control
System
™
(SCS)
for wall cleaning
(rough to smooth
surfaces)
LEDs indicating
pump strength for
SCS
1
Figure 12. Submerge and Remove Trapped Air
2