background image

To ensure proper water flow:

Use rigid PVC pipe with a minimum 
diameter of 3/4", 1-1/2" is recommended, for
the dedicated return line. Flexible PVC piping
is not recommended as it can be damaged by
expansion and movement caused by the
surge of pump pressure. Poly pipe is not
recommended because it has clamps that
can fail.

Polaris is not responsible for

damages caused by the use of such
materials.

The booster pump inlet connection line
should be at least 3/4" pipe.

The Softube

®

quick connect is designed to work 
with the Polaris reinforced hose 
(part #P19) only.

Do not tap into the top of a horizontal line.

Use 90° street ells to minimize bends and
loops in the Polaris reinforced hose.

Recommended plumbing configurations.

Installing the Pump

1.

Mount the pump using four concrete
expansion anchors to ensure stability.

2.

Slide the quick connect retainer ring over the
Softube quick connect threads. Install quick
connects onto pump discharge and supply
ports using clear silicone as a thread sealant.

3.

Measure and cut reinforced hose ensuring 
cut is clean, with no more than a 30º off
straight edge. Avoid unnecessary loops or
bends in the hose.

4.

Push the hose onto the quick connect until it
is flush against the hose barb base.

5.

Holding the hose in place, 

pull and twist

the

sleeve on the quick connect over the hose as
far as possible. Snap the clip into place.

Checking Water Flow

After the system is plumbed, verify water flow to
the booster pump by turning on the filtration pump
and disconnecting the inlet supply line at the
pump. Water should flow from the line.

If there is no flow:

Verify that the installation is correct.

Install a ball valve on the return line after the
booster pump inlet.

Use smaller eyeball fittings in the pool return
lines or plug a return line.

Once flow is established, the pump is ready for
operation.

Horizontal
Leg

To Booster
Pump

Polaris
Reinforced
Hose

Pool Return

From Filter or Heater

To Spa

Ground
Level

Street Ell

Option #1

Pool Return

From Filter or Heater

Option #3

Option #2

To Spa

Ground Level

Leave 6"

Sleeve

Hose Barb

Retainer

Clip Ring

Threads

Hose

Preferred Configuration

Alternative Configuration

Retainer Clip

Sleeve

Hose

Summary of Contents for PB4-60Q

Page 1: ...me clock is recommended to control the On Off functions of the booster pump A manual switch can also be used If a time clock is used set it to turn the pump on half an hour after the pool filtration pump is turned on and turn the pump off at least half an hour before the filtration pump shuts off Periodically check the time clock settings to make sure they are properly synchronized Plumbing The Po...

Page 2: ...hread sealant 3 Measure and cut reinforced hose ensuring cut is clean with no more than a 30º off straight edge Avoid unnecessary loops or bends in the hose 4 Push the hose onto the quick connect until it is flush against the hose barb base 5 Holding the hose in place pull and twist the sleeve on the quick connect over the hose as far as possible Snap the clip into place Checking Water Flow After ...

Page 3: ...the consumer must deliver or ship the unit or the warranty parts freight prepaid to the nearest Polaris Authorized Service Center or return it freight prepaid after proper authorization to the plant of manufacture Authorization to return a unit to the plant of manufacture must be obtained from the Polaris Customer Service Department For your convenience please check with your dealer for the local ...

Page 4: ...Quick Connect Retainer 4 R OTAT I O N Inlet 13 1 3 6 2 8 9 10 12 11 9 14 4 7 Outlet 16 17 18 15 No Part Description Qty Polaris Booster Pump Part PB4 60 No Part Description Qty 1 P5 Volute Includes Drain Plug 1 2 P15 Impeller 1 3 P55 Seal Stainless Steel Cup Spring 1 4 P95 O Ring Bracket 1 5 P10 Bracket 1 6 P35 Bolt Stainless Bracket to Motor 2 7 P40 O Ring for Shaft 1 8 P61 Motor 3 4 HP Threaded ...