9928487 R01 - 2018 RANGER XP 1000 Service Manual
© Copyright Polaris Industries Inc.
3.117
HVAC COVER MOUNT REPLACEMENT
1. Remove
the
compressor
drive
belt.
Refer
to
“Compressor Drive Belt Replacement”, page
3.112
procedure.
2. Remove
the
alternator.
Refer
to
procedure.
3. Remove the compressor. Refer to
procedure.
4. Remove the drive pulley fastener and pulley from the
cover mount, using Crankshaft Pulley Holder
PU-
52254
to assist.
5. Remove the fasteners holding the HVAC cover mount
to the engine.
6. If necessary, remove the fasteners holding the timing
wheel and adapter hub to the engine.
7. For installation, reverse removal procedure.
8. Torque
NEW
timing wheel fasteners to specification.
TORQUE
HVAC Timing Wheel Fasteners:
9 lb-ft (12 Nm)
9. Torque
the
HVAC
cover
mount
fasteners
to
specification in the sequence shown.
TORQUE
HVAC Cover Mount Fasteners:
9 lb-ft (12 Nm)
10. Torque the drive pulley fastener to specification using
Crankshaft Pulley Holder
PU-52254
.
TORQUE
HVAC Drive Pulley Fastener:
44 lb-ft (60 Nm) + 180°