3.122
9928487 R01 - 2018 RANGER XP 1000 Service Manual
© Copyright Polaris Industries Inc.
6.
If removing the evaporator coil, remove the fasteners
holding the evaporator coil to the heater coil.
7.
To Install, reverse procedure. Tighten fasteners to
specification.
TORQUE
Expansion Valve Pressure Hoses:
12 ft-lb (16 Nm)
Expansion Valve Tubes:
22 ft-lb (30 Nm)
8.
Recharge the A/C system.
HEATER / EVAPORATOR UNIT REPLACEMENT
HEATER / EVAPORATOR UNIT REMOVAL
1. Remove the refrigerant from the A/C system.
WARNING
In the event of a leak, wear safety goggles. Escaping
refrigerant can cause severe injuries to eyes. In contact
with a flame, R-134a refrigerant gives a toxic gas.
2. Drain
the
cooling
system.
Refer
to
Removal / Installation, page 3.88
procedure.
3. Remove the upper and lower dash. Refer to
procedure.
4. Disconnect the blower unit connector to the wire
harness.
5. Remove the fasteners
q
holding the air distributor
manifold to the heater / evaporator unit.
6. Remove the clamps holding the coolant hoses to the
heater / evaporator unit through the front wheel
opening.