5.32
9928487 R01 - 2018 RANGER XP 1000 Service Manual
© Copyright Polaris Industries Inc.
HELIX AND MOVABLE SHEAVE BUSHING
INSPECTION
1. Inspect the Teflon® coating
q
on the moveable
sheave bushing. Inspect Sheave for signs of wear,
grooving or cracking. De-glaze sheave surfaces with
a 3M Scotch-Brite™ Pad if needed. Replace if
needed.
Moveable Sheave Bushing Inspection:
Replace the cover bushing if more brass than Teflon®
is visible on the bushing. Refer to Bushing Service,
2. Inspect the Teflon® coating
w
on the Helix bushing.
Inspect Helix for signs of wear, grooving or notching
on ramps. De-glaze sheave surfaces with a 3M
Scotch-Brite™ Pad if needed. Replace if needed.
Helix Bushing Inspection:
Replace the Helix bushing if more brass than Teflon® is
visible on the bushing. Refer to Bushing Service, page
BUSHING SERVICE
MOVABLE SHEAVE BUSHING REMOVAL
1. Install hand end of Piston Pin Puller (PN
2870386
)
securely into the bench vise and lightly grease the
puller threads.
2. Install main adapter
q
onto puller.
3. Slide the sheave onto the puller as shown.
4. Install the bushing adapter
w
(PN
5020635
).
5. Install spacer and securing nut.
6. Firmly
grip
the
movable
sheave
and
turn
counterclockwise to remove the bushing.
7. Remove nut from puller rod and set aside.
8. Pull bushing removal tool and adapter from puller rod.
Remove and discard bushing.
MOVABLE SHEAVE BUSHING INSTALLATION
1. Install bushing adapter
w
(PN
5020635
) on Piston
Pin Puller.
2. Apply Loctite® 648 evenly to bushing bore inside
moveable sheave.
3. Set bushing in place on sheave.
4. Install Movable Sheave on puller as shown.