background image

These operating instructions are published by CEI Conrad Electronic International (HK) Limited, 18th Floor, Tower 2, 

Nina Tower, No. 8 Yeung Uk Road, Tsuen Wan, New Territories, Hong Kong. All rights including translation reserved. 

Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require 

the prior written approval by the editor. Reprinting, also in part, is prohibited. The operating instructions reflect the current 

technical specifications at time of print.
Copyright 2017 by CEI Conrad Electronic International (HK) Limited 

*1494211_v1_0317_02_DS_m_4L_(1)

Mounting and connection

  Read the information in the "Preparation for mounting" section.
  Ensure that no existing cables or pipes (including water pipes) are damaged when 

drilling mounting holes or securing screws.

•  Unscrew the two side screws using a Phillips 

screwdriver, and then pull the wall mount out of the 

housing.

•  Make sure that the mains supply is switched off.
•  Use the wall mount as a template to mark the fixing 

points on the surface. Pay attention to the orientation 

of the light housing.

•  Drill two holes for the dowels into the mounting 

surface. (If you are using a wooden surface, you can 

screw the base directly to the surface without using 

dowels. However, you should still drill holes even 

when using wood. The dowels are not required in 

this case.)

•  Insert the dowels into the drilled holes.
•  Pierce the cable hole with a round, pointed object.
•  Guide the mains cable through the hole.
•  Secure the wall mount to the surface using the 

screws provided.

10 mm

6 mm

•  Remove the outer insulation on the wires to a 

maximum length of about 16 mm (if necessary). Strip 

the insulation on each of the three wires on the mains 

cable to a length of about 6 mm (no more than 8 

mm). The earth cable (yellow-green cable) should be 

at least 6 mm longer so that it remains the last cable 

in the screw terminal in the event of a fault.

•  The neutral wire should be connected to "N", the live 

wire (phase) to "L", and the protective earth to the 

clamping point with the " " symbol.

•  Position the light with the side screws in the correct 

orientation on the wall mount.

•  Turn on the power supply to the light. The light is now 

ready to use.

  We recommend that you install a switch to turn the light on and off. If you wish to 

connect a plug (not included) to the mains cable, ensure that there is an extension 

cable or a mains socket available near to where the light is mounted. These 

components are not included with the product.

Operation

•  To turn on the light, turn on the power supply corresponding to your setup method, e.g. turn 

on the switch, insert the mains plug or activate the connected switching device (infra-red 

sensor switch). (These components are not included with the product.)

L = brown
N = blue

 = green / yellow

Care and cleaning

•  Before cleaning the light, turn off the mains voltage (or disconnect it from the mains) and let 

it cool down sufficiently.

•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could 

damage the casing or cause the light to malfunction.

•  Use a dry, lint-free cloth to clean the product.
•  Never point a garden hose or pressure washer at the product (e.g. for cleaning).
•  Do not wear metallic or conductive jewellery such as necklaces, bracelets or rings when 

carrying out maintenance work on the product (including cleaning).

Maintenance

•  The LED bulbs are not replaceable. 
•  Replace the transparent protective cover if there are any signs of damage.
•  All other maintenance or repair work should be done by a technician. Repairs must only be 

carried out using original replacement parts.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in household 

waste. Always dispose of the product according to the relevant statutory regulations.

 
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage ......................... 220 - 240 V/AC, 50 Hz
Protection rating ........................... IP44
Protection class ............................ I
Power consumption ...................... Max. 7 W
Housing material ........................... Stainless steel, polycarbonate (cover)
Illuminant ...................................... 30 LEDs (not dimmable)
Lifespan ........................................ 25,000 hours
Luminous flux ............................... 450 lm
Colour temperature ....................... 2700 - 3000 K (warm white)
Operating conditions .....................  -20 to +40 °C, 0–100 % relative humidity (non-condensing) 
Storage conditions ........................  -25 to +40 °C, 0–100 % relative humidity (non-condensing) 
Dimensions (L x W x H) ................ 115 x 76 x 110 mm
Weight .......................................... Approx. 319 g

Distributed by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau

Summary of Contents for 1494211

Page 1: ...rgrund sind die mitgelieferten Schrauben und oder Dübel zu verwenden Die Leuchte muss in der bauseitigen Unterverteilung mit einer 10 16A Sicherung abgesichert werden Davor muss ein Fehlerstromschutzschalter FI Schutzschalter angebracht sein Verwenden Sie ein dreiadriges Netzkabel mit 3 x 1 mm Querschnitt zum Anschluss der LED Außenwandleuchte Die Installation der Leuchte darf nur im spannungsfrei...

Page 2: ...führende Draht Phase an der mit L und der Schutzleiter an der mit gekennzeichneten Klemmstelle zu befestigen Setzen Sie die Leuchte mit den seitlichen Schrauben in der richtigen Orientierung wieder auf die Wandbefestigung Schalten Sie die Stromversorgung der Leuchte frei Die Leuchte ist nun betriebsbereit Es ist zu empfehlen einen Schalter zum Ein Ausschalten der Netzzuleitung der Leuchte zu insta...

Page 3: ...device to ensure that the power supply is isolated Operating Instructions LED exterior wall lamp 7 W Item no 1494211 Intended use This product is designed for use as an indoor and outdoor light The light is IP44 certified and can be mounted and operated both indoors and outdoors The IP protection rating is only guaranteed when the product is installed correctly Using metal structures as live condu...

Page 4: ... on the wall mount Turn on the power supply to the light The light is now ready to use We recommend that you install a switch to turn the light on and off If you wish to connect a plug not included to the mains cable ensure that there is an extension cable or a mains socket available near to where the light is mounted These components are not included with the product Operation To turn on the ligh...

Page 5: ...tribution secondaire du bâtiment Un disjoncteur différentiel à courant résiduel doit être monté au préalable Utilisez un câble d alimentation à 3 fils de 1 mm de section pour connecter la lampe d extérieure murale à LED L installation de la lampe doit être seulement effectuée hors tension Pour cela il ne suffit pas d éteindre seulement l interrupteur Mettre le câble d alimentation électrique hors ...

Page 6: ...dans le bon sens sur la fixation murale Mettre la lampe sur tension La lampe est maintenant prête à fonctionner Il est conseillé d équiper la lampe d un interrupteur pour allumer éteindre l alimentation électrique Si vous souhaitez utiliser une fiche d alimentation non incluse dans la livraison pour le raccordement au câble d alimentation assurez vous qu une rallonge ou qu une prise est à proximit...

Page 7: ...allatie van de lamp mag uitsluitend worden uitgevoerd als de betreffende stroomgroep spanningsvrij is Het is niet voldoende om alleen de lichtschakelaar uit te schakelen Schakel de stroomtoevoer compleet uit door de desbetreffende zekering van het circuit eruit te halen resp de zekeringautomaat uit te schakelen Schakel vervolgens de desbetreffende aardlekschakelaar uit Beveilig de zekeringkast teg...

Page 8: ...ing Schakel de stroom naar de lamp weer in De lamp is nu gereed voor gebruik Het wordt aanbevolen een schakelaar voor het in uitschakelen van de stroomkabel naar de lamp toe te installeren Als u voor het aansluiten van de stroomkabel een stekker niet inbegrepen wilt gebruiken dient u ervoor te zorgen dat er in de buurt van de montageplek een verlengkabel of stopcontact aanwezig is Deze componenten...

Reviews: