background image

10

:

:

:

YES

NO

YES

NO

1

2

3

4

5

6

7

8

YES

NO

1

2

3

4

5

6

7

8

9

                 PRODUCT INSTALLATION / DELIVERY CONTROL FORM

DATE             :

SIGNATURE  :

DATE             :

SIGNATURE  :

TURNSTILES ARE FREE OF SCRATCHES, DENTS  OR OTHER DAMAGE

ALL PHOTOCELLS ARE FREE OF OBSTRUCTION/ No direct sunlight on Master sensors

FAIL SAFE EXIT CHECK:
WINGS OPEN AUTOMATICALLY (HG AND SG) OR OPEN EASILY BY HAND (PG) WHEN 
POWER IS CUT OFF

POWER LEAKAGE TEST: 
CHASSIS/METAL PARTS ARE FREE OF AC VOLTAGE LEAKAGE MEASURED IN REFERENCE TO 
GROUND

SAFETY PHOTOSENSOR CHECK:
WINGS REMAIN OPEN IF A PERSON STANDS IN THE MIDDLE OF THE LANE

FREE PASS MODE CHECK:
INDICATORS TURN GREEN. WINGS OPEN AUTOMATICALLY WHEN A PERSON ENTERS THE 
LANE AND CLOSE UPON EXIT

EMERGENCY INPUTS (CONTINUOUS NC CONTACT - EMG mode active when open): 
WINGS OPEN, ALL INDICATORS TURN GREEN, PERIODIC ALARM SOUND

WINGS OPEN AND CLOSE SMOOTHLY 
WITHOUT EXCESSIVE NOISE OR VIBRATION

CONROL INPUT A AND INPUT B:
INDICATORS TURN GREEN IN DIRECTION OF PASSAGE ; RED X ON THE OPPOSITE SIDE 

MASTER DIAGNOSTICS SCREEN FREE OF ERROR CODES

APPROVED BY

REPORTED BY

REMARKS

POWER ON: 
ALL INDICATORS LIT, BUZZERS SOUND, WINGS CYCLE ONCE AND STOP IN STANDBY  
POSITION

REMARKS

DESCRIPTION

NORMALLY CLOSED (NC) INPUT

 -Remove jumper when 

connected to 

re alarm system-Normally open (NO) in units 

produced before April 2016

HG AND SG MODELS HAVE RGB ILLUMINATED WINGS 
AND LED STRIPES UNDER TOP LID

PASSAGE LANE AND PHOTOCELLS MUST BE CLEAR 
DURING START UP

DESCRIPTION

:

INSTALLATION CHECKLIST

FUNCTIONAL CONTROL CHECKLIST

ALL COVERS AND PANELS ARE CORRECTLY INSTALLED

MASTER / SLAVE DATA CABLES
AND CONTROL INPUTS ARE CORRECTLY CONNECTED

:

PRODUCT MODEL NO 

:

INSTALLER HAS POLIMEK TECHNICAL TRAINING CERTIFICATE

ALL WIRING IS PROPERLY LAID OUT AND CONNECTED

TURNSTILES ARE PROPERLY POSITIONED / ALL ANCHORING BOLTS ARE 
TIGHT AND SECURE

INSTALLATION SURFACES FLAT AND EVEN WITH SUFFICIENT STRENGTH

POWER CABLES ARE PROPERLY GROUNDED AND INSULATED

INSTALLATION LOCATION

NAME OF INSTALLER     
INSTALLATION DATE      

SERIAL NUMBER
FIRMWARE VERSION 

    

CONTROL AND SECURITY SYSTEMS MANUFACTURER 

Summary of Contents for SG55

Page 1: ...1 SLIDING GATE INSTALLATION AND MAINTENANCE HANDBOOK WARRANTY CERTIFICATE www polimek com tr KK 1302 0005 R 4 Y T 05 08 2020 CONTROL AND SECURITY SYSTEMS MANUFACTURER...

Page 2: ...ery Control Form 10 Annual Maintenance Table 11 Internal Wiring Diagrams 12 Motor Driver Adjustments 21 Power Supply Unit 22 Dip Switch Settings Operation Modes 23 24 User Control Terminals 25 Install...

Page 3: ...CONTROL AND SECURITY SYSTEMS MANUFACTURER...

Page 4: ...ble PWM motor drive system Passage Width 550 mm Wing Height 900 mm 0 8 seconds factory default Wing Height 1200 mm 1 0 seconds factory default Wing Height 2000 mm 1 2 seconds factory default The above...

Page 5: ...5 SLIDING GATE SG 55 TECHNICAL SPECIFICATIONS DD 72 358 R 1 Page 3 3 Y T 04 05 17 Design and specifications are subject to change without notice CONTROL AND SECURITY SYSTEMS MANUFACTURER...

Page 6: ...CONTROL AND SECURITY SYSTEMS MANUFACTURER SOUND DIAGNOSTIC UNIT...

Page 7: ...ser can select fail closed mode by internal dip switch Wing Speed Wing speed is electronically controlled by adjustable PWM motor drive system The above figures are for standard tempered glass wings F...

Page 8: ...8 SLIDING GATE SG 90 TECHNICAL SPECIFICATIONS DD 72 340 R 1 Page 3 3 Y T 04 05 17 CONTROL AND SECURITY SYSTEMS MANUFACTURER...

Page 9: ...9...

Page 10: ...EEN IN DIRECTION OF PASSAGE RED X ON THE OPPOSITE SIDE MASTER DIAGNOSTICS SCREEN FREE OF ERROR CODES APPROVED BY REPORTED BY REMARKS POWER ON ALL INDICATORS LIT BUZZERS SOUND WINGS CYCLE ONCE AND STOP...

Page 11: ...ch rollers wing stabilizers o Deformed rubber roller o excessive pressure on one or both rollers Replace pinch roller Adjust for slight and equal pressure on both sides of glass wing Ensure that glass...

Page 12: ...TROL BOARD HDG 2010 USER CONTROL 1 I O TERMINAL USER CONTROL 2 PROX SWITCH BATTERY M MOTOR 8 GLASS WING CB 19 RGB LED STRIP 3 4 LEFT SIDE RIGHT SIDE 1 2 3 4 1 2 3 4 CB 20 RGB LED STRIP TOP INDICATORS...

Page 13: ...HDG 2010 USER CONTROL 1 I O TERMINAL USER CONTROL 2 BATTERY M MOTOR GLASS WING CB 19 RGB LED STRIP 3 4 LEFT SIDE RIGHT SIDE 1 2 3 4 1 2 3 4 CB 20 RGB LED STRIP TOP INDICATORS RGB LED STRIP TOP INDICAT...

Page 14: ...c BLUE 2 Batt Out N C CABLE COLORS 3 12Vdc N C 1 N c ORANGE 4 Gnd BLACK 2 24vdc WHITE 3 N c BLACK 4 24v RED CABLE COLORS 5 Handshake Data GREEN 1 Gnd BLACK 6 Gnd YELLOW 2 12Vdc RED 7 Tx BLUE 8 Rx BROW...

Page 15: ...CABLE COLORS 1 12Vdc BLUE 2 Sw_b YELLOW 3 Gnd GREEN 4 Sw_a RED 5 Gnd BLACK 6 Vcc WHITE DIRECTION SENSORS PROX SWITCH 1 DIRECTION SENSORS PROX SWITCH 9 DIRECTION SENSORS PROX SWITCH 12 1 12 9 FDC 12 PI...

Page 16: ...OLORS CABLE COLORS 1 BROWN 1 BLACK 2 BLUE 2 RED 3 BLACK 4 1 Encoder B ENCODER ENCODER DATA Gnd Encoder A Pass Tx Main Tx Gnd Gnd 5Vdc M S COMM ENCODER ENCODER DATA Gnd Encoder A 11 24Vdc 24Vdc BRAKE G...

Page 17: ...RECEIVER MASTER UNIT ALL RECEIVER MODULES RECEIVER UNITS Receive Data 2 MAIN COMM Main Rx Pass Rx Ind_led Gnd 24Vdc Rx 11 M S COMM Tx 6 PHOTOCELL CONTROL Gnd I O1 Gnd I O2 5Vdc 5Vdc 24Vdc Main Tx Pass...

Page 18: ...M Pass Tx Main Tx Pass Rx R 1 8 RECEIVER UNITS Receive Data 11 IR TRANSMITTER SLAVE UNIT ALL RECEIVER MODULES RECEIVER UNITS Receive Data Ind_led Main Tx Gnd Gnd Main Rx 5Vdc Main Rx 6 MAIN COMM 2 MAI...

Page 19: ...SOUND DIAGNOSTIC UNIT 8 REAR VIEW FRONT VIEW CABLE COLORS 1 BLACK 2 RED 3 GREEN 4 YELLOW 6 8 SOUND DIAGNOSTIC UNIT Gnd Tx 5Vdc Rx 8 REAR VIEW FRONT VIEW CABLE COLORS 1 BLACK 2 RED 3 GREEN 4 YELLOW 3...

Page 20: ...YELLOW 6 N C Proximity Sensor B Rx Tx 9 Gnd SENSOR DATA 24Vdc Proximity Sensor A Gnd 24Vdc 24Vdc 24Vdc I O1 Gnd I O2 Gnd 4 MOTOR OUT 7 MAIN CONTROL 5Vdc 5Vdc ENCODER DATA 3 Power IN 24Vdc Gnd Ext I O...

Page 21: ...LV TRQ E Push for select min max value D U D U Select value by button Push to set exit goto setup menu High speed set for direction A Low speed set for direction A Start Ramp set for direction A Stop...

Page 22: ...22 24VDC 6 5 AMP CABLE COLORS 1 24Vdc BLUE 2 24Vdc GRAY 3 Gnd BROWN 4 Gnd BLACK MAIN POWER SMPS POWER CABLE SMPS UNIT 2 3 4 1...

Page 23: ...23...

Page 24: ...ion Mode 2 Controlled Controlled Controlled Free Pass MASTER SLAVE A B B A Mode 3 Controlled Free Pass SW SW 7 8 MODE 1 OFF OFF NO MODE ON OFF MODE 2 OFF ON MODE 3 ON ON SLAVE SIDE SW 8 ON Fast free p...

Page 25: ...rol Input A B Min 100ms Normally Open Contact Control Input B A Min 100ms Normally Open Contact Inhibit A B Inhibit B A Do Not Use Dry Contact B A Passage Complete Dry Contact A B Passage Complete 5Vd...

Page 26: ...CAUTION Drawing is for general information Actual dimensions may vary according to model Use template provided with unit for drilling SURFACE MOUNTING INFORMATION POLIMEK TURNSTILE ALL RIGHTS RESERVE...

Page 27: ...27 ANCHORING...

Page 28: ...28 Master IR RX Slave IR TX Master IR RX Slave IR TX Avoid direct sunlight or other IR light sources that could interfere with the IR receivers inside Master unit CORRECT INCORRECT...

Page 29: ...29...

Page 30: ......

Page 31: ...o o o oz K RK R R R K K K K K K K K oz Ka 3 3 K o RK K K K K R K K R K KK 1302 0005 R 4 Y T 05 08 2020 CONTROL AND SECURITY SYSTEMS MANUFACTURER Atat rk Organize Sanayi B lgesi 10024 Sokak No 9 i li...

Reviews: