21
D
Motor and brake may be unplugged to move wing for testing purposes.
CAUTION!
Mechanism should be checked to be free and smooth before changing settings on the motor driver board.
MOTOR DRIVER CONTROL
MENU
U
E
D
2 X 8
LCD
P: 12500
I: 0.41 A
POSITION
CURRENT
Lcd view at
Standby
Push "E" button for 3 seconds
to entry setup menu
ADJ MODE
D U
SP A MAX
SP A MIN
RP A STR
RP A STP
TRQ ADJ
RP B STP
RP B STR
SP B MIN
SP B MAX
RLV TRQ
E
Push
for select
min max
value
D
U
D
U
Select value by
button
Push to set & exit
goto setup menu
High speed
set for
direction A
Low speed
set for
direction A
Start
Ramp
set for
direction A
Stop
Ramp
set for
direction A
High speed
set for
direction B
Low speed
set for
direction B
Start
Ramp
set for
direction B
Stop
Ramp
set for
direction B
Torque
setting of
both
direction
Relative
torque
setting of
both
direction
D
or
U
E
Push "E" button f or
exit setup menu
Up button
Down button
Enter button
Checking Motor Encoder: P (Position) values increase as wing moves out. P=
0 at full open position. P=MAX value when closed.
Summary of Contents for SG55
Page 3: ...CONTROL AND SECURITY SYSTEMS MANUFACTURER...
Page 6: ...CONTROL AND SECURITY SYSTEMS MANUFACTURER SOUND DIAGNOSTIC UNIT...
Page 9: ...9...
Page 23: ...23...
Page 27: ...27 ANCHORING...
Page 29: ...29...
Page 30: ......