Politec S.r.l. | Manual Ales – Ver. 1.7.2
13
8.
ENVIRONMENTAL DISQUALIFICATION
To obtain the message in the control panel of environmental disqualification, you must insert the jumper in DIS
ON and connect a "OPEN COLLECTOR NEGATIVE" to the output DIS OUT. This feature allows output to
the control panel of environmental disqualification, for which the barrier is in a standby state, this will avoid
annoying false alarms caused by weather conditions.
9.
ADDITIONAL TAMPER
On mother boards TX and RX there is a supplementary Tamper input useful to add a wall tamper. In case of
absence of additional Tamper, Check the closing of the contact by a jumper.
1. Insert jumper in DIS ON.
2. With the supplied cable connect
the output OUT DIS (open
collector negative) to bring the
output in the control panel
Tamper input additional, in case of absence
MUST be closed by jumpers.
.