Politec Srl | Manual MANA DT SMA + DT3
–
Ver 2.5.2
16
MICROWAVE
10.2
TX MOTHERBOARD
1
POWER SUPPLY
The power connector is linked to power supplier via a flat cable.
2
MW CONNECTOR
The connectors "MW" or Output 1 / 2 are used to connect the cavity
transmission. Normally uses the output "Output 1", and only in case of
double barrier microwave using the synchronized output "Output 2".
3
LED
The "Led insert jumpers", inserted in position 2-3, enables the power of
Led Output "and" Led VDC ", indicating the presence of their tensions.
Return after the test at rest 1-2. NB The "Output LED" has a lower
light intensity of Led VDC, when the cavity "TX" is inserted.
4
DIP SWITCH
The "channel selector" allows you to select the desired channel by
switching to "ON".
NB The
selected channel must be the same as that of the Circuit "Rx”.
1
4
3
2