13
POLITEC s.r.l
•
The "Input Connector Mw" is used to connect the receiver cavity.
•
"Output Connector”:
1-2, NC alarm contact
3-4, tamper contacts.
•
The power connector is connected to power via a flat cable.
•
The “Functiones selector” allows you to check the voltage supply, the
value of sensitivity, goodness of the signal, the walk test and the test
alignment (see table previous page).
•
The "Channel selector" allows you to choose the desired channel by
switching to"ON". NB The selected channel must be the same as that of
the Circuit "Tx".
•
The "Channel LED" indicates that the channel is tuned with the
transmitter.
•
The "LED Alarm" indicates that the system is not in alarm (when there is
the alarm LED goes off).
•
The "Voltmeter" indicates the voltage in volts of the selected function (see
table previous page).
•
The "Led Alignment" indicates the signal strength received:
Red = weak signal;
Yellow = signal Fair;
Green = Strong Signal.
•
Potentiometers (Gain, Walk Test, sensitivity, delay), adjustments to be
made during installation
•
The "Buzzer" (or buzzer) is activated with the "Walk Test" (selector
functions):
Continuous beep = Alarm
Sound intermittently variable = Tell sensitive area.